Desa CGN10A, CGN6 installation manual Connecting to GAS Supply, Gas Connection

Page 8

CGN10A AND CGN6

NATURAL GAS HEATER

CONNECTING TO GAS

SUPPLY

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/ or fittings.

NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas.

IMPORTANT: Check gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe 3/8" diameter or greater to allow proper gas vol- ume to heater. If pipe is too small, undue loss of pressure will oc- cur.

3/8" NPT

Pipe

Nipple

Ground Joint Union

Manual Shutoff Valve *

From Gas Meter

(4" W.C. to 10.5" W.C. Pressure)

3" Minimum

Pressure

Regulator

Heater

Cabinet

Tee Joint

 

 

 

 

 

 

 

 

Reducer

 

Test

Bushing to

 

 

Gauge

1/8" NPT

 

 

Connection *

 

 

 

 

1/8" NPT

 

 

Plug Tap

 

 

 

 

 

 

Tee

 

 

 

 

 

 

Joint

 

 

Pipe

 

Sediment Trap

 

Nipple

 

 

Cap

 

 

 

 

 

 

Installation must include a manual shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 12).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 12. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessory, page 15.

Figure 12 - Gas Connection

8

101870

Image 8
Contents Blue Flame VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information CGN10A and CGN6 Natural GAS HeaterProduct Features Product IdentificationFresh AIR for Combustion and Ventilation Local CodesConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing to Wall Installation ItemsInstalling Heater to Wall Check GAS TypeInstalling Bottom Mounting Screw Attaching to wall anchor methodPlacing Heater On Mounting Screws Removing Front Panel Of HeaterConnecting to GAS Supply Gas ConnectionPressure Testing GAS Supply Piping System Pressure Testing Heater GAS ConnectionsFor Your Safety Read Before Lighting Checking GAS ConnectionsManual Lighting Procedure Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Specifications Replacement PartsTechnical Service Service PublicationsODS/PILOT Illustrated Parts ListHeater Exploded View Parts Available not Shown Parts Centrals FBD101870 Warranty Information Keep this Warranty

CGN6, CGN10A specifications

Desa CGN10A and CGN6 are two innovative models in the Desa line of heating appliances, combining cutting-edge technology with user-friendly features designed to enhance the heating experience in a variety of settings. These appliances are particularly noted for their versatility and efficiency, making them suitable for both residential and commercial applications.

The Desa CGN10A stands out with its impressive heating capacity, providing an excellent solution for larger spaces. It is engineered with advanced venting technology that ensures optimal airflow, allowing the unit to quickly and evenly distribute heat throughout the room. This model features an adjustable thermostat and fan settings, enabling users to customize their heating experience according to their specific needs. The eco-friendly design reduces energy consumption while maintaining superior performance, making it a smart choice for environmentally conscious consumers.

On the other hand, the Desa CGN6 is perfect for smaller areas or more limited spaces. Despite its compact size, it does not compromise on heating power or efficiency. This model utilizes a highly efficient combustion system that maximizes fuel usage, translating into lower operational costs for users. Additionally, its lightweight and portable design makes it suitable for various settings, whether it's in a workshop, garage, or even outdoor gatherings.

Both models are equipped with safety features that ensure peace of mind during operation. They include automatic shut-off functions and safety sensors that detect issues such as overheating or improper venting. Furthermore, the appliances are designed with user accessibility in mind, featuring intuitive controls and easy-to-read displays that simplify the operating process.

In terms of aesthetics, both the CGN10A and CGN6 boast sleek designs that can seamlessly integrate into a range of interior styles. The durable construction ensures longevity, making these models a reliable investment for years to come.

In conclusion, Desa CGN10A and CGN6 models exemplify the perfect blend of efficiency, technology, and design. With their responsive heating capabilities, user-friendly features, and emphasis on safety, they stand out as leaders in the heating appliance market, catering to diverse user needs while prioritizing sustainability.