MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

12"

 

 

 

 

 

 

8"

 

 

 

 

Mantel Shelf

18"

 

20"

22"

 

8"

 

14"

17"

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

24" 24" Model

20" 18" Model

Top of Fireplace

Opening

Determining Minimum Mantel Clearance when Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7 when using a hood.

NOTICE: Surface temperatures of adjacent walls and

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

Mantel Shelf

mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an acceptable height

remove the mantel

FLOOR CLEARANCES

 

12"

 

 

 

10"

 

 

 

8"

 

 

 

6"

 

 

 

2 1/2"

 

 

Minimum Non-

 

 

 

Combustible

 

 

 

Material

8"

12"

15"

 

 

Min.

 

 

 

Hood

Distances to

 

(GA6050, GA6052,

 

Underside of

 

or GA6053)

 

Mantel

 

 

18"

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

20" 18" and 24" Models

Top of Fireplace Opening

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible floor- ing (see Figure 9).

Figure 7 - Minimum Mantel Clearances When Using Hood

 

Combustible

Hearth

14"

Material

 

Combustible

Min.

 

Material

 

 

5"

 

 

Min.

Noncombustible Material

 

Figure 8 - Minimum Fireplace

Figure 9 - Minimum Fireplace

Clearances If Installed at Floor

Clearances Above

Level

 

Combustible Flooring

For morevisit www..com

107068

Image 9
Contents CLD3924PTA, CLD3924NTA OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Winchester Oak Model ShownSafety Information Table of ContentsProduct Identification Local Codes Product FeaturesUnpacking AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Confined Space and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Firebox Size Minimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Determining Minimum Mantel Clearance when Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemEquipment Shutoff Valve Pressure Testing Heater Gas ConnectionsFit over the burner see . Make sure the front What to do if YOU Smell GAS Operating HeaterVariable Control Operation Lighting InstructionsTo Turn OFF GAS to Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burners Only pilot stays litThermostat Control Operation Inspecting Burners Cleaning MaintenanceTechnical Service Service HintsReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbModel CGS2718P CLD3018PA CGS3124P CLD3924PTA SpecificationsIllustrated Parts Breakdown Variable Manually-Controlled Winchester Oak Models Parts ListCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA KEY Part Number CLD3924NTA CLD3924PTA Description QTY Parts Central AccessoriesOwners Registration Form Postage Required 107068 Warranty Information

CLD3018NA 24, CLD3924NTA, CLD3924PTA specifications

The Desa CLD3018NA, CLD3924PTA, and CLD3924NTA are advanced heating solutions designed to provide efficient warmth for residential and commercial spaces. These models stand out for their innovative features, reliable performance, and cutting-edge technologies.

The CLD3018NA is renowned for its compact design and powerful heating capabilities. With a heat output of up to 30,000 BTUs, it efficiently warms areas up to 1,200 square feet. Its dual-fuel capability allows it to operate on either natural gas or propane, making it versatile for different settings. The adjustable thermostat provides precise temperature control, ensuring optimal comfort. Additionally, the CLD3018NA features an easy-to-use ignition system for quick startups and a blower fan to enhance heat circulation.

Moving on to the CLD3924PTA, this model offers a larger heating capacity, capable of delivering up to 35,000 BTUs. It is ideal for medium to large spaces, effectively heating areas of up to 1,500 square feet. One notable characteristic of the CLD3924PTA is its aesthetic appeal, with a sleek design that can complement various interior styles. The unit comes equipped with an automatic shut-off feature for safety, ensuring that users can enjoy peace of mind while using it. Furthermore, the adjustable heat output allows for customized comfort in changing weather conditions.

The CLD3924NTA variant takes efficiency to the next level. With similar heating capabilities as the CLD3924PTA, it boasts enhanced energy efficiency ratings. It incorporates advanced insulation technology to minimize heat loss, making it an eco-friendly choice for conscientious consumers. The built-in air filter helps maintain indoor air quality by reducing dust and allergens, which is particularly beneficial for households with allergy sufferers. Additionally, the CLD3924NTA is designed for quiet operation, ensuring that users can enjoy warmth without the distraction of noisy machinery.

All three models benefit from Desa's commitment to quality and reliability. Built using durable materials and subjected to rigorous testing, they are engineered for longevity and consistent performance. Easy installation and maintenance further enhance their appeal, making these heaters a practical choice for any homeowner or business owner in need of a dependable heating solution. In summary, the Desa CLD3018NA, CLD3924PTA, and CLD3924NTA represent the pinnacle of heating technology, combining efficiency, safety, and aesthetic value to enhance any environment.