Desa CLD3018NA 24, CLD3924PTA, CLD3924NTA Fit over the burner see . Make sure the front

Page 14

14

INSTALLATION

Installing Logs, Models CGS2718P, CGS2718N, CGS3124P and CGS3124N (Cont.) Installing Logs, Models CLD3018PA, CLD3018NA, CLD3924PTA and CLD3924NTA

INSTALLATION

Continued

2.Locate the notches on the back of the front log (#2). Slide these notches over the tabs of the grate base (see Figure 19).

3.Locate the notches in the bottom of the crossover log (#3). Place the crossover log on top of the back log and front log. Make sure the notches of the crossover log line up with rectangular knobs on top of the back and front logs (see Figure 20).

4.Add lava rock around base of heater if desired. Do not place lava rock on logs or burner.

Front Log (#2)

Notch

Tabs of

Grate Base

Figure 19 - Installing Front Log

INSTALLING LOGS, MODELS CLD3018PA, CLD3018NA, CLD3924PTA AND CLD3924NTA

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, reposition logs ac- cording to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.

Place the base of the middle log (#1) in the U-shaped slots of

 

the grate base. The cutout on the right of the middle log should

 

fit over the burner (see Figure 21). Make sure the front of the

 

middle log is resting on the tabs of the grate base and the cut-

 

out area is centered over the burner “U” bend.

2.

Locate pegs on the bottom of back log (#2). Slide these pegs

Crossover Log (#3)

Notch

Notch

Rectangular Knob

 

into the holes in the grate base behind the burner (see Figure 22,

 

page 15).

3.

Locate the notches in the bottom of the front log (#3). Place the

 

front log on the grate fingers. Make sure the notches of the front

 

log line up with the grate fingers (see Figure 23, page 15).

4.

Place crossover log (#4) onto the pin (right) on back log (#2) and

 

into the recess of the middle log (#1) (see Figure 24, page 15).

5.

Add lava rock around base of heater if desired. Do not place

 

any lava rock on logs or burner.

Middle Log (#1)

Rectangular Knob

Figure 20 - Installing Crossover Log

Tab

Burner

“U” Bend

U-Shaped Slot

Figure 21 - Installing Middle Log (#1)

For..com

107068

Image 14
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualCLD3924PTA, CLD3924NTA Winchester Oak Model ShownTable of Contents Safety InformationProduct Identification Unpacking Product FeaturesLocal Codes AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined Space and Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsMinimum Firebox Size Check GAS TypeMinimum Fireplace Clearance to Combustible Materials If Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Equipment Shutoff ValveFit over the burner see . Make sure the front Operating Heater What to do if YOU Smell GASLighting Instructions Variable Control OperationShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off Burners Only pilot stays litThermostat Control Operation Cleaning Maintenance Inspecting BurnersReplacement Parts Technical ServiceService Hints Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceSpecifications Model CGS2718P CLD3018PA CGS3124P CLD3924PTAIllustrated Parts Breakdown Parts List Variable Manually-Controlled Winchester Oak ModelsCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA KEY Part Number CLD3924NTA CLD3924PTA Description QTY Accessories Parts CentralOwners Registration Form Postage Required 107068 Warranty Information

CLD3018NA 24, CLD3924NTA, CLD3924PTA specifications

The Desa CLD3018NA, CLD3924PTA, and CLD3924NTA are advanced heating solutions designed to provide efficient warmth for residential and commercial spaces. These models stand out for their innovative features, reliable performance, and cutting-edge technologies.

The CLD3018NA is renowned for its compact design and powerful heating capabilities. With a heat output of up to 30,000 BTUs, it efficiently warms areas up to 1,200 square feet. Its dual-fuel capability allows it to operate on either natural gas or propane, making it versatile for different settings. The adjustable thermostat provides precise temperature control, ensuring optimal comfort. Additionally, the CLD3018NA features an easy-to-use ignition system for quick startups and a blower fan to enhance heat circulation.

Moving on to the CLD3924PTA, this model offers a larger heating capacity, capable of delivering up to 35,000 BTUs. It is ideal for medium to large spaces, effectively heating areas of up to 1,500 square feet. One notable characteristic of the CLD3924PTA is its aesthetic appeal, with a sleek design that can complement various interior styles. The unit comes equipped with an automatic shut-off feature for safety, ensuring that users can enjoy peace of mind while using it. Furthermore, the adjustable heat output allows for customized comfort in changing weather conditions.

The CLD3924NTA variant takes efficiency to the next level. With similar heating capabilities as the CLD3924PTA, it boasts enhanced energy efficiency ratings. It incorporates advanced insulation technology to minimize heat loss, making it an eco-friendly choice for conscientious consumers. The built-in air filter helps maintain indoor air quality by reducing dust and allergens, which is particularly beneficial for households with allergy sufferers. Additionally, the CLD3924NTA is designed for quiet operation, ensuring that users can enjoy warmth without the distraction of noisy machinery.

All three models benefit from Desa's commitment to quality and reliability. Built using durable materials and subjected to rigorous testing, they are engineered for longevity and consistent performance. Easy installation and maintenance further enhance their appeal, making these heaters a practical choice for any homeowner or business owner in need of a dependable heating solution. In summary, the Desa CLD3018NA, CLD3924PTA, and CLD3924NTA represent the pinnacle of heating technology, combining efficiency, safety, and aesthetic value to enhance any environment.