Desa installation manual Specifications, Model CGS2718P CLD3018PA CGS3124P CLD3924PTA

Page 25

SPECIFICATIONS

25

SPECIFICATIONS

 

18" Model

18" Model

24" Model

24" model

 

(CGS2718P)

(CLD3018PA)

(CGS3124P)

(CLD3924PTA)

Btu (Variable)

16,000/27,000

16,000/30,000

16,000/31,500

20,000/39,000

Type Gas

Propane/LP Only

Propane/LP Only

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure

8.0" W.C.

8.0" W.C.

8.0" W.C.

8.0" W.C.

Inlet Gas Pressure

 

 

 

 

(in. of water)

 

 

 

 

Maximum

14"

14"

14"

14"

Minimum*

11"

11"

11"

11"

Shipping Weight

27 lbs.

29 lbs.

29lbs.

27 lbs.

* For the purpose of input adjustment

 

 

 

 

18" Model

18" Model

24" Model

24" Model

 

(CGS2718N)

(CLD3018NA)

(CGS3124N)

(CLD3924NTA)

Btu (Variable)

16,000/27,000

16,000/30,000

16,000/31,500

20,000/39,000

Type Gas

Natural Gas Only

Natural Gas Only

Natural Gas Only

Natural Gas Only

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure

3.5" W.C.

3.5" W.C.

3.5" W.C.

3.5" W.C.

Inlet Gas Pressure

 

 

 

 

(in. of water)

 

 

 

 

Maximum

10.5"

10.5"

10.5"

10.5"

Minimum*

5"

5"

5"

5"

Shipping Weight

27 lbs.

27 lbs.

29 lbs.

29lbs

* For the purpose of input adjustment

For morevisit www..com

107068-01D

Image 25
Contents CLD3924PTA, CLD3924NTA OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Winchester Oak Model ShownSafety Information Table of ContentsProduct Identification Local Codes Product FeaturesUnpacking AIR for Combustion and VentilationConfined Space and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Fireplace Clearance to Combustible Materials Check GAS TypeMinimum Firebox Size Minimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Determining Minimum Mantel Clearance when Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemEquipment Shutoff Valve Pressure Testing Heater Gas ConnectionsFit over the burner see . Make sure the front What to do if YOU Smell GAS Operating HeaterVariable Control Operation Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burners Only pilot stays litThermostat Control Operation Inspecting Burners Cleaning MaintenanceService Hints Technical ServiceReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbModel CGS2718P CLD3018PA CGS3124P CLD3924PTA SpecificationsIllustrated Parts Breakdown Variable Manually-Controlled Winchester Oak Models Parts ListCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA KEY Part Number CLD3924NTA CLD3924PTA Description QTY Parts Central AccessoriesOwners Registration Form Postage Required 107068-01D Warranty Information