Desa CGS3124P installation manual KEY Part Number CLD3018NA CLD3018PA Description QTY

Page 29

PARTS LIST

Models CLD3018NA and CLD3018PA

29

PARTS LIST

Variable Manually-Controlled Royal English

Oak Model

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.

KEY

PART NUMBER

 

 

NO.

CLD3018NA

CLD3018PA

DESCRIPTION

QTY.

1

104933-02

104933-02

Middle Log (#1)

1

2

104934-02

104934-02

Back Log (#2)

1

3

104932-02

104932-02

Front Log (#3)

1

4

104935-02

104935-02

Crossover Log (#4)

1

5

102844-02

102844-02

Lower Bracket

1

6

102775-04CK

102775-01CK

Painted Base Assembly

1

7

098867-14

098867-10

Gas Regulator

1

8

102798-01

102798-01

Inlet Tube

1

9

102779-03

102779-01

Outlet Burner Tube

1

10

099056-26

099056-16

Burner Orifice Injector

1

11

102843-01

102843-01

Burner Clip

1

12

102980-01

102772-01

Burner

1

13

102568-07

102568-05

Control Valve

1

14

098508-01

098508-01

Valve Retainer Nut

1

15

098354-01

098354-01

Control Knob

1

16

102445-01

102445-01

Piezo Ignitor

1

17

099387-08

099387-08

Pilot Tube

1

18

098271-10

098271-10

Ignitor Cable

1

19

104285-01

104286-01

ODS Pilot

1

20

M11084-38

M11084-38

Screw, Hex Head (#8-18 x .38)

8

21

098276-01

098276-01

Hex Head Plug, 1/8" NPT

1

22

098249-01

098249-01

Nut, M5

2

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

100563-01

100563-01

Warning Plate

1

 

101055-02

101055-02

Lighting Instructions Plate

1

 

100565-01

100565-01

Warning Plate Fastener

1

 

100639-01

100639-01

Caution Decal

1

 

101449-04

101449-04

Control Position Decal

1

 

101137-02

101137-02

Hardware Kit

1

 

GA6060

GA6060

Lava Rock

1

 

 

 

 

 

For morevisit www..com

107068-01D

Image 29
Contents CLD3924PTA, CLD3924NTA OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Winchester Oak Model ShownSafety Information Table of ContentsProduct Identification Local Codes Product FeaturesUnpacking AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined Space and Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Firebox Size Check GAS TypeMinimum Fireplace Clearance to Combustible Materials Minimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Determining Minimum Mantel Clearance when Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemEquipment Shutoff Valve Pressure Testing Heater Gas ConnectionsFit over the burner see . Make sure the front What to do if YOU Smell GAS Operating HeaterVariable Control Operation Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burners Only pilot stays litThermostat Control Operation Inspecting Burners Cleaning MaintenanceReplacement Parts Technical ServiceService Hints Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbModel CGS2718P CLD3018PA CGS3124P CLD3924PTA SpecificationsIllustrated Parts Breakdown Variable Manually-Controlled Winchester Oak Models Parts ListCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA KEY Part Number CLD3924NTA CLD3924PTA Description QTY Parts Central AccessoriesOwners Registration Form Postage Required 107068-01D Warranty Information