INSTALLATION
Check Gas Type Installation and Clearances
7
INSTALLATION
Continued
WARNING: Seal any fresh air vents or ash clean- out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a
WARNING: Never install the heater
•in a bedroom or bathroom unless installed as a vented appliance (Variable
•in a recreational vehicle
•where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the heater
•in high traffic areas
•in windy or drafty areas
CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
IMPORTANT:
CHECK GAS TYPE
Use only the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION AND CLEARANCES
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining wall.
MINIMUM FIREPLACE
CLEARANCE TO
COMBUSTIBLE MATERIALS
Log Size | Side Wall | Ceiling |
|
|
|
18", 24" | 16" | 42" |
LOG SIZING REQUIREMENTS
|
| Minimum Firebox Size | |||
Log |
|
|
| Front | Rear |
Size | Height | Depth | Width | Width* | |
|
|
|
|
|
|
18" |
| 17" | 14" | 24" | 20" |
24" |
| 17" | 14" | 28" | 21" |
|
|
|
|
|
|
*Measured at 14" Depth
Carefully follow the instructions below. This will ensure safe installation into a masonry,
Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling
A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 8.
Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace cabinet (see Figure 8).
Note: When installing your gas logs into a manufactured fire- box, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.
B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.
|
|
|
|
|
|
|
|
|
| 121/4 |
|
|
|
|
|
|
|
|
|
|
| 101/2 |
|
| Example |
|
|
|
|
|
| 8 3/4 |
| ||
|
|
|
|
|
|
| 7 |
| |||
|
|
|
|
|
|
|
|
|
| INCHES | |
|
|
|
|
|
|
|
|
|
| 51/4 | |
|
|
|
|
|
|
|
|
|
| 31/2 | |
|
|
|
|
|
|
|
|
|
| 13/4 | |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 7/8 |
|
|
|
|
|
|
|
|
|
|
| 7/16 |
|
FIREBOX | .5 | 1 | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 * |
|
|
|
|
| INCHES |
|
|
|
|
|
*Minimum 16 inches from Side Wall
Figure 4 - Minimum Clearance for Combustible to Wall
For morevisit www..com