Desa UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER installation manual Operating Heater

Page 22

OPERATING HEATER

22

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

WARNING

WARNING ICON

G 001

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE

During initial operation of new heater, burning logs will give off a paper- burning smell. Open damper or window to vent smell. This will only last a few hours.

Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3. Press in and turn control knob clockwise

to the OFF position.

Ignitor Button

Control Knob

 

 

HIPILOT

 

OFF

 

LO

Figure 21 - Control Knob and Ignitor Button Location Continued

103309

Image 22
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFLAME-MAX Oak Log DesignContents Safety Information Safety InformationProduct Identification Unpacking FeaturesLocal Codes ProductUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Check GAS TypeLOG Sizing Requirements Minimum Fireplace ClearanceTo Combustible Materials Minimum Wall and Ceiling Clearances see FigureMinimum Non Combustible Material Clearances If Using Mantel Installing Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS Supply Installation Items NeededChecking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs For Standard Oak Log ModelInstalling Premium One-Piece Log Set For Premium ModelsFor Your Safety Read Before Lighting Operating HeaterVariable Control Operation Operating Heater Inspecting Burners Pilot Flame PatternODS/PILOT and Burner Trouble ShootingQualified service person should service and repair heater LogsMaintenance, TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Technical ServiceReplacement Parts HintsIllustrated Parts Breakdown Parts List KEY Part Number for VYS18N VYS24N Description QTYBirch Log Models VYD24N and VYBD24N KEY Part Number for VYD24N VYBD24N Description QTY Hood GA6050 AccessoriesValve GA5010 Hood GA6052103309 Warranty Information Keep this Warranty

UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER specifications

The Desa Unvented (Vent-Free) Natural Gas Log Heater is an innovative heating solution that combines efficiency, comfort, and aesthetic appeal. Designed for those seeking a reliable and stylish way to heat their living spaces, this vent-free heater is ideal for any home setting.

One of the main features of the Desa Unvented Gas Log Heater is its ability to provide warmth without the need for external venting. This means it can be installed in a variety of locations, including areas without a traditional chimney or flue. The absence of vents not only simplifies installation but also maximizes design flexibility, allowing homeowners to enhance their existing decor with a beautiful gas log fireplace.

The heater utilizes advanced infrared heating technology, which ensures that radiant heat is emitted throughout the room. This method of heating is exceptionally efficient, as it warms up objects and people directly, rather than merely heating the air. Consequently, this results in faster heating times and greater comfort, especially during colder months.

Equipped with the latest safety features, the Desa Unvented Gas Log Heater includes an oxygen depletion sensor (ODS), which automatically shuts off the heater if oxygen levels drop too low. This feature guarantees peace of mind for users, ensuring that safety is prioritized without sacrificing comfort.

Another significant characteristic of this heater is its realistic log design, which mimics the look of traditional wood-burning fireplaces. The ceramic fiber logs are intricately detailed, providing an authentic and charming ambiance that enhances any room's aesthetic. This realistic flame effect not only adds to the visual appeal but also creates a cozy atmosphere perfect for gatherings with family and friends.

The heater is designed to operate efficiently with minimal maintenance. The adjustable thermostat allows for precise temperature control, ensuring that users can set their desired warmth level and maintain it effortlessly. Moreover, the unit is compatible with natural gas, making it an environmentally friendly option that reduces the carbon footprint compared to traditional heating methods.

In summary, the Desa Unvented Natural Gas Log Heater is an exceptional heating option that combines elegance, safety, and performance. With its vent-free design, advanced heating technology, realistic aesthetics, and user-friendly features, this heater is a perfect choice for those looking to create a warm and inviting environment in their homes.