Desa CLD3018PT, CLD3018NT Minimum Noncombustible Material Clearances, If Not Using Mantel

Page 8

8

INSTALLATION

Installation and Clearances (Cont.)

INSTALLATION

Continued

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fire- place opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" model only). See Figure 5 at right for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 10.

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" model only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7 on page 9 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Noncombustible material okay.

Between 8" and 12"

24" Model: Install fireplace hood

 

accessory (GA6050, GA6052,

 

or GA6053, see Accessories,

 

page 32).

 

18" Model: Noncombustible

 

material okay.

Less than 8"

Noncombustible material must

 

be extended to at least 8". See

 

Between 8" and 12", above. If

 

you cannot extend material, you

 

must operate heater with flue

 

damper open.

 

 

Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

For..com

107068-01H

Image 8
Contents OWNER’S Operation and Installation Manual CLD3924PTA, CLD3924NTAWhat to do if YOU Smell GAS Winchester Oak Model ShownTable of Contents Safety InformationProduct Identification Product Features Local CodesUnpacking AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined Space and Unconfined Space Installation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Firebox Size Check GAS TypeMinimum Fireplace Clearance to Combustible Materials If Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance when Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Equipment Shutoff ValveInstalling Front Log Operating Heater What to do if YOU Smell GASLighting Instructions Variable Control OperationManual Lighting Procedure To Turn OFF GAS To ApplianceShutting Off Heater Shutting Off Burners Only pilot stays litThermostat Control Operation Cleaning Maintenance Inspecting BurnersReplacement Parts Technical ServiceService Hints Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceSpecifications Illustrated Parts Breakdown Parts List Variable Manually-Controlled Winchester Oak ModelsCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA CLD3018PTParts List Accessories Parts CentralOwners Registration Form Postage Required 107068-01H Warranty Information

SGS3124N, SGS3124P, CLD3018NT, CLD3018PT specifications

The Desa CLD3018PT, CLD3018NT, SGS3124N, and SGS3124P are innovative heating solutions designed for both practicality and efficiency. These products cater to the distinct needs of consumers looking for reliable heating options for their living spaces, workshops, or garages.

The CLD3018PT and CLD3018NT models stand out due to their portability and lightweight design. They feature advanced heating technology that ensures quick and consistent warmth, making them an ideal choice for temporary or supplemental heating. The CLD3018PT is equipped with a propane tank connection for efficient energy use, while the CLD3018NT integrates natural gas functionality, providing versatility in fuel source depending on consumer needs. Both models utilize an advanced safety system that includes automatic shut-off mechanisms and tip-over protection, making them safe for indoor and outdoor use.

On the other hand, the SGS3124N and SGS3124P models are designed for more permanent heating solutions. The SGS3124N operates on natural gas, making it an excellent choice for homeowners looking to minimize their carbon footprint. The SGS3124P provides a propane option, catering to users who may not have a natural gas line available. Both models are built with durable materials that ensure longevity and performance, even under heavy use. Their efficient heating technologies are capable of warming larger spaces quickly, making them suitable for workshops and other substantial areas.

In terms of features, all four models incorporate user-friendly controls that allow for easy temperature adjustment and settings management. The presence of safety features in these products reinforces their reliability, accommodating users' needs without compromising on safety.

Overall, the Desa CLD3018PT, CLD3018NT, SGS3124N, and SGS3124P represent a fusion of innovation, safety, and efficiency in the heating market. These models cater to a diverse range of heating needs, appealing to various customers from casual users who require portability to homeowners seeking a permanent heating solution. By emphasizing advanced technology and user safety, Desa continues to uphold its reputation for providing high-quality heating appliances.