Desa SGS3124N, CLD3018PT, CLD3018NT, SGS3124P installation manual Thermostat Control Operation

Page 18

18

OPERATING HEATER Thermostatically-Controlled Models

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Thermostat Control Operation

Manual Lighting Procedure

OPERATING HEATER

Continued

5. Turn control knob counterclockwise C-clockwiseto the PILOT position. Press in control knob for five (5) seconds (see Fig- ure 27).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8. Turn control knob counterclockwise C-clockwiseto desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

 

HI

OL

OFF

 

Pilot

Ignitor Button

Control Knob

 

Figure 27 - Control Knob and Ignitor Button Location

Ignitor Electrode Pilot Burner

Ignitor Electrode

Pilot

 

 

Burner

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions be- ginning on page 17.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions, column 1.

Propane/LP

Thermocouple

Natural Gas

Figure 28 - Pilot

For..com

107068-01H

Image 18
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualCLD3924PTA, CLD3924NTA Winchester Oak Model ShownTable of Contents Safety InformationProduct Identification Unpacking Product FeaturesLocal Codes AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Confined Space and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Firebox Size If Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Equipment Shutoff ValveInstalling Front Log Operating Heater What to do if YOU Smell GASLighting Instructions Variable Control OperationShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off Burners Only pilot stays litThermostat Control Operation Cleaning Maintenance Inspecting BurnersTechnical Service Service HintsReplacement Parts Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceSpecifications Illustrated Parts Breakdown Parts List Variable Manually-Controlled Winchester Oak ModelsCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA CLD3018PTParts List Accessories Parts CentralOwners Registration Form Postage Required 107068-01H Warranty Information

SGS3124N, SGS3124P, CLD3018NT, CLD3018PT specifications

The Desa CLD3018PT, CLD3018NT, SGS3124N, and SGS3124P are innovative heating solutions designed for both practicality and efficiency. These products cater to the distinct needs of consumers looking for reliable heating options for their living spaces, workshops, or garages.

The CLD3018PT and CLD3018NT models stand out due to their portability and lightweight design. They feature advanced heating technology that ensures quick and consistent warmth, making them an ideal choice for temporary or supplemental heating. The CLD3018PT is equipped with a propane tank connection for efficient energy use, while the CLD3018NT integrates natural gas functionality, providing versatility in fuel source depending on consumer needs. Both models utilize an advanced safety system that includes automatic shut-off mechanisms and tip-over protection, making them safe for indoor and outdoor use.

On the other hand, the SGS3124N and SGS3124P models are designed for more permanent heating solutions. The SGS3124N operates on natural gas, making it an excellent choice for homeowners looking to minimize their carbon footprint. The SGS3124P provides a propane option, catering to users who may not have a natural gas line available. Both models are built with durable materials that ensure longevity and performance, even under heavy use. Their efficient heating technologies are capable of warming larger spaces quickly, making them suitable for workshops and other substantial areas.

In terms of features, all four models incorporate user-friendly controls that allow for easy temperature adjustment and settings management. The presence of safety features in these products reinforces their reliability, accommodating users' needs without compromising on safety.

Overall, the Desa CLD3018PT, CLD3018NT, SGS3124N, and SGS3124P represent a fusion of innovation, safety, and efficiency in the heating market. These models cater to a diverse range of heating needs, appealing to various customers from casual users who require portability to homeowners seeking a permanent heating solution. By emphasizing advanced technology and user safety, Desa continues to uphold its reputation for providing high-quality heating appliances.