Desa CLD3018NT Mantel Clearances, Floor Clearances, Determining Minimum Mantel Clearance

Page 9

INSTALLATION

9

Mantel Clearances

Floor Clearances

 

 

 

INSTALLATION

Continued

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

12"

 

 

 

 

 

 

8"

 

 

 

 

Mantel Shelf

18"

 

20"

22"

 

8"

 

14"

17"

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

24" 24" Model

20" 18" Model

Top of Fireplace

Opening

Determining Minimum Mantel Clearance when Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Fig- ure 7 when using a hood.

NOTICE: Surface temperatures of adjacent walls and

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

Mantel Shelf

mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an acceptable height

remove the mantel

FLOOR CLEARANCES

 

12"

 

 

 

10"

 

 

 

8"

 

 

 

6"

 

 

 

2 1/2"

 

 

Minimum Non-

 

 

 

Combustible

 

 

 

Material

8"

12"

15"

 

 

Min.

 

 

 

Hood

Distances to

 

(GA6050, GA6052,

 

Underside of

 

or GA6053)

 

Mantel

 

 

18"

Underside of

Mantel Shelf

All minimum distances are in inches

Log Set

20" 18" and 24" Models

Top of Fireplace Opening

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible floor- ing (see Figure 9).

Figure 7 - Minimum Mantel Clearances When Using Hood

 

Combustible

Hearth

14"

Material

 

Combustible

Min.

 

Material

 

 

5"

 

 

Min.

Noncombustible Material

 

Figure 8 - Minimum Fireplace

Figure 9 - Minimum Fireplace

Clearances If Installed at Floor

Clearances Above

Level

 

Combustible Flooring

For morevisit www..com

107068-01H

Image 9
Contents CLD3924PTA, CLD3924NTA OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Winchester Oak Model ShownSafety Information Table of ContentsProduct Identification Local Codes Product FeaturesUnpacking AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Confined Space and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Firebox Size Minimum Noncombustible Material Clearances If Not Using MantelMantel Clearances Determining Minimum Mantel Clearance when Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemEquipment Shutoff Valve Pressure Testing Heater Gas ConnectionsInstalling Front Log What to do if YOU Smell GAS Operating HeaterVariable Control Operation Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burners Only pilot stays litThermostat Control Operation Inspecting Burners Cleaning MaintenanceTechnical Service Service HintsReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbSpecifications Illustrated Parts Breakdown Variable Manually-Controlled Winchester Oak Models Parts ListCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3018PT CLD3924NTA CLD3924PTAParts List Parts Central AccessoriesOwners Registration Form Postage Required 107068-01H Warranty Information

SGS3124N, SGS3124P, CLD3018NT, CLD3018PT specifications

The Desa CLD3018PT, CLD3018NT, SGS3124N, and SGS3124P are innovative heating solutions designed for both practicality and efficiency. These products cater to the distinct needs of consumers looking for reliable heating options for their living spaces, workshops, or garages.

The CLD3018PT and CLD3018NT models stand out due to their portability and lightweight design. They feature advanced heating technology that ensures quick and consistent warmth, making them an ideal choice for temporary or supplemental heating. The CLD3018PT is equipped with a propane tank connection for efficient energy use, while the CLD3018NT integrates natural gas functionality, providing versatility in fuel source depending on consumer needs. Both models utilize an advanced safety system that includes automatic shut-off mechanisms and tip-over protection, making them safe for indoor and outdoor use.

On the other hand, the SGS3124N and SGS3124P models are designed for more permanent heating solutions. The SGS3124N operates on natural gas, making it an excellent choice for homeowners looking to minimize their carbon footprint. The SGS3124P provides a propane option, catering to users who may not have a natural gas line available. Both models are built with durable materials that ensure longevity and performance, even under heavy use. Their efficient heating technologies are capable of warming larger spaces quickly, making them suitable for workshops and other substantial areas.

In terms of features, all four models incorporate user-friendly controls that allow for easy temperature adjustment and settings management. The presence of safety features in these products reinforces their reliability, accommodating users' needs without compromising on safety.

Overall, the Desa CLD3018PT, CLD3018NT, SGS3124N, and SGS3124P represent a fusion of innovation, safety, and efficiency in the heating market. These models cater to a diverse range of heating needs, appealing to various customers from casual users who require portability to homeowners seeking a permanent heating solution. By emphasizing advanced technology and user safety, Desa continues to uphold its reputation for providing high-quality heating appliances.