INSTALLING

Installing Two Mounting Screws

Note: Wall anchors and mounting screws are in hardware package. The hardware

TO WALL

package is provided with heater.

Continued Attaching to wall stud method

 

For attaching mounting screw to wall stud

 

1.

Drill hole at marked location using 9/64" drill bit.

 

2.

Insert mounting screw into wall stud.

 

3.

Tighten screw until 1/16" space (thickness of penny) is between screwhead and

 

 

wall.

Attaching to wall anchor method

Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry).

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep.

2.Fold wall anchor (see Figure 6).

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

Figure 6 - Folding Anchor

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 7). IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

5.Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 8).

Thin Walls

(1/4" to 1/2" thick)

Figure 7 - Popping Open Anchor Wings For Thin Walls

Thin or Thick Wall (thick wall shown)

1/16" Space

Solid Wall

ANCHOR

Figure 8 - Tightening Anchors

Continued

11

099404

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual Model CGN10Contents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationProducing Adequate Ventilation Fresh AIR ForCombustion VentilationDetermining if You Have a Confined or Unconfined Space Fresh AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRCheck GAS Type Installing To WallInstallation Items Never install the heater A bathroom A recreational vehicleMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsConnections Pressure Testing Heater GAS ConnectionsChecking GASOperating Heater For Your Safety Read Before LightingOperating HeaterShutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterCorrect Burner Flame Pattern Burner Flame PatternAir Passageways Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice CabinetTROUBLE- Shooting See CleaningObserved Possible Remedy Problem Cause Trouble Shooting Parts Not Under Warranty Technical ServiceService Hints Replacement Parts Parts Under WarrantyValve GA5010 Service Publications AccessoryParts Centrals Heater Exploded View Parts List CGN10 Keep this Warranty Warranty Information

CGN10 specifications

Desa CGN10 represents a significant advancement in the realm of sustainable energy solutions, particularly within the context of decentralized energy generation. This innovative concept is engineered to promote efficiency and sustainability, making it a noteworthy option for both urban and rural applications.

One of the defining features of Desa CGN10 is its versatility. The system can be deployed in various environmental contexts, accommodating diverse energy needs ranging from residential to industrial applications. Its modular design allows for scalability, enabling users to customize their energy generation capabilities according to their specific requirements.

Incorporating cutting-edge renewable energy technologies, Desa CGN10 offers multi-source energy generation, including solar, wind, and bioenergy. The integration of these sources enhances energy reliability and diminishes dependence on traditional fossil fuels. The solar component utilizes high-efficiency photovoltaic panels, designed to capture maximum sunlight and convert it into usable energy. Wind turbines included in the system leverage advanced aerodynamic designs for improved performance in varying wind conditions. Additionally, bioenergy capabilities allow for the conversion of organic waste into energy, fostering circular economy principles.

Another significant characteristic of the Desa CGN10 is its advanced energy management system (EMS). This intelligent framework optimizes energy generation and consumption, ensuring that the available resources are used in the most efficient manner. The EMS employs real-time data analytics, allowing for predictive maintenance, which in turn minimizes downtime and enhances overall system reliability.

Furthermore, Desa CGN10 prioritizes user experience through a user-friendly interface that grants users control over their energy production and consumption. This interface provides insights into energy usage patterns, enabling users to make informed decisions and contribute to energy conservation efforts.

Overall, Desa CGN10 is a forward-thinking solution that represents a fusion of innovative technologies and sustainable practices. It empowers communities and businesses to harness renewable energy, reduce carbon footprints, and take significant strides toward energy independence. As the world shifts toward cleaner energy solutions, Desa CGN10 is poised to play a crucial role in the transition to a more sustainable future.