PARTS LIST CGN10

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

1

098304-01

Screw, #10 x 3/8"

2

2

099467-02

Front Panel Assembly

1

3

099318-04

Grill Guard

1

4

098342-01

Grill Guard Clip

2

5

098533-03AA

Bottom Glass Retainer

1

6

098260-03

Glass Panel

1

7

098532-03AA

Top Glass Retainer

1

8

M11084-38

Screw, #8 x 3/8"

8

9

098352-03BR

Deflector Unit

1

10

098271-03

Ignitor Cable

1

11

098249-01

Nut, M5

2

12

099440-03

ODS/Pilot Assembly

1

12-1

098514-01

Thermocouple

1

12-2

098594-01

Ignitor Electrode

1

13

099386-02

Burner

1

14

099387-05

Pilot Tubing

1

15

098251-03

Injector

1

16

099463-01

Injector Holder

1

17

099415-01

Pressure Regulator

1

18

099462-01

Burner Tubing

1

19

099391-02

Regulator Tubing

1

20

098276-01

1/8" NPT Plug

1

21

099057-01

Pressure Tap Fitting

1

22

099413-01

Control Valve

1

23

099468-01

Cabinet

1

24

097159-02

Piezo Ignitor

1

25

099393-01

Control Knob

1

26

098508-01

Valve Retainer Nut

1

27

098303-02

Screw, #6 x 5/16"

2

28

099553-01

Pilot Shield

1

29

099818-01

Internal Tooth Washer

1

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

099395-03

Control Position Label

1

 

 

 

 

12-1

12-2

ODS/PILOT

099404

27

Image 27
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual Model CGN10Contents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationProducing Adequate Ventilation Fresh AIR ForCombustion VentilationFresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRCheck GAS Type Installing To WallInstallation Items Never install the heater A bathroom A recreational vehicleMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsConnections Pressure Testing Heater GAS ConnectionsChecking GASOperating Heater For Your Safety Read Before LightingOperating HeaterShutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterCorrect Burner Flame Pattern Burner Flame PatternAir Passageways Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice CabinetTROUBLE- Shooting See CleaningObserved Possible Remedy Problem Cause Trouble Shooting Parts Not Under Warranty Technical ServiceService Hints Replacement Parts Parts Under WarrantyService Publications Accessory Parts CentralsValve GA5010 Heater Exploded View Parts List CGN10 Keep this Warranty Warranty Information

CGN10 specifications

Desa CGN10 represents a significant advancement in the realm of sustainable energy solutions, particularly within the context of decentralized energy generation. This innovative concept is engineered to promote efficiency and sustainability, making it a noteworthy option for both urban and rural applications.

One of the defining features of Desa CGN10 is its versatility. The system can be deployed in various environmental contexts, accommodating diverse energy needs ranging from residential to industrial applications. Its modular design allows for scalability, enabling users to customize their energy generation capabilities according to their specific requirements.

Incorporating cutting-edge renewable energy technologies, Desa CGN10 offers multi-source energy generation, including solar, wind, and bioenergy. The integration of these sources enhances energy reliability and diminishes dependence on traditional fossil fuels. The solar component utilizes high-efficiency photovoltaic panels, designed to capture maximum sunlight and convert it into usable energy. Wind turbines included in the system leverage advanced aerodynamic designs for improved performance in varying wind conditions. Additionally, bioenergy capabilities allow for the conversion of organic waste into energy, fostering circular economy principles.

Another significant characteristic of the Desa CGN10 is its advanced energy management system (EMS). This intelligent framework optimizes energy generation and consumption, ensuring that the available resources are used in the most efficient manner. The EMS employs real-time data analytics, allowing for predictive maintenance, which in turn minimizes downtime and enhances overall system reliability.

Furthermore, Desa CGN10 prioritizes user experience through a user-friendly interface that grants users control over their energy production and consumption. This interface provides insights into energy usage patterns, enabling users to make informed decisions and contribute to energy conservation efforts.

Overall, Desa CGN10 is a forward-thinking solution that represents a fusion of innovative technologies and sustainable practices. It empowers communities and businesses to harness renewable energy, reduce carbon footprints, and take significant strides toward energy independence. As the world shifts toward cleaner energy solutions, Desa CGN10 is poised to play a crucial role in the transition to a more sustainable future.