Desa CGN10 installation manual TROUBLE- Shooting, See Cleaning

Page 21

TROUBLE- SHOOTING

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Continued

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.ODS/pilot is clogged

6.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Clean ODS/pilot (see Cleaning and Mainte- nance, page 20) or replace ODS/pilot assembly

6.Replace gas regulator

ODS/pilot lights but

1.

Control knob not fully

1.

Press in control knob

flame goes out when

 

pressed in

 

fully

control knob is

2.

Control knob not

2.

After ODS/pilot lights,

released

 

pressed in long enough

 

keep control knob

 

 

 

 

pressed in 30 seconds

 

3.

Manual shutoff valve

3.

Fully open manual

 

 

not fully open

 

shut-off valve

 

4.

Thermocouple connec-

4.

Hand tighten until

 

 

tion loose at control

 

snug, then tighten 1/4

 

 

valve

 

turn more

 

5.

Pilot flame not touch-

5.

A) Contact local

 

 

ing thermocouple,

 

natural gas company

 

 

which allows thermo-

 

 

 

 

couple to cool, causing

 

B) Clean ODS/pilot

 

 

pilot flame to go out.

 

(see Cleaning and

 

 

This problem could be

 

Maintenance, page 20)

 

 

caused by one or both

 

or replace ODS/pilot

 

 

of the following:

 

assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially

 

 

 

 

clogged ODS/pilot

 

 

 

6.

Thermocouple dam-

6.

Replace thermocouple

 

 

aged

 

 

 

7.

Control valve damaged

7.

Replace control valve

Continued

099404

21

Image 21
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual Model CGN10Contents Safety Information Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemCombustion Fresh AIR ForVentilation Producing Adequate VentilationFresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRInstallation Items Installing To WallNever install the heater A bathroom A recreational vehicle Check GAS TypeMarking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsChecking Pressure Testing Heater GAS ConnectionsGAS ConnectionsOperating Heater For Your Safety Read Before LightingOperating HeaterPilot Flame Pattern Operating Heater Inspecting BurnerShutting Off Heater Shutting Off Burner Only pilot stays litCorrect Burner Flame Pattern Burner Flame PatternODS/PILOT and Burner Orifice Cleaning and Maintenance Trouble ShootingCabinet Air PassagewaysTROUBLE- Shooting See CleaningObserved Possible Remedy Problem Cause Trouble Shooting Service Hints Replacement Parts Technical ServiceParts Under Warranty Parts Not Under WarrantyService Publications Accessory Parts CentralsValve GA5010 Heater Exploded View Parts List CGN10 Keep this Warranty Warranty Information

CGN10 specifications

Desa CGN10 represents a significant advancement in the realm of sustainable energy solutions, particularly within the context of decentralized energy generation. This innovative concept is engineered to promote efficiency and sustainability, making it a noteworthy option for both urban and rural applications.

One of the defining features of Desa CGN10 is its versatility. The system can be deployed in various environmental contexts, accommodating diverse energy needs ranging from residential to industrial applications. Its modular design allows for scalability, enabling users to customize their energy generation capabilities according to their specific requirements.

Incorporating cutting-edge renewable energy technologies, Desa CGN10 offers multi-source energy generation, including solar, wind, and bioenergy. The integration of these sources enhances energy reliability and diminishes dependence on traditional fossil fuels. The solar component utilizes high-efficiency photovoltaic panels, designed to capture maximum sunlight and convert it into usable energy. Wind turbines included in the system leverage advanced aerodynamic designs for improved performance in varying wind conditions. Additionally, bioenergy capabilities allow for the conversion of organic waste into energy, fostering circular economy principles.

Another significant characteristic of the Desa CGN10 is its advanced energy management system (EMS). This intelligent framework optimizes energy generation and consumption, ensuring that the available resources are used in the most efficient manner. The EMS employs real-time data analytics, allowing for predictive maintenance, which in turn minimizes downtime and enhances overall system reliability.

Furthermore, Desa CGN10 prioritizes user experience through a user-friendly interface that grants users control over their energy production and consumption. This interface provides insights into energy usage patterns, enabling users to make informed decisions and contribute to energy conservation efforts.

Overall, Desa CGN10 is a forward-thinking solution that represents a fusion of innovative technologies and sustainable practices. It empowers communities and businesses to harness renewable energy, reduce carbon footprints, and take significant strides toward energy independence. As the world shifts toward cleaner energy solutions, Desa CGN10 is poised to play a crucial role in the transition to a more sustainable future.