Desa TC275J, REM2000, RCP2000 owner manual Trouble Shooting, Symptom Possible Cause Remedy

Page 9

TROUBLE-

SHOOTING

You may have further ques- tions about this heater. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

WARNING

Never attempt to service heater while it is connected to propane supply, operating, or hot. Severe burns can occur.

SYMPTOM

POSSIBLE CAUSE

REMEDY

Pilot fails

1. Propane supply valve closed

1.

Open propane supply valve

to light.

 

on propane tank(s).

 

slowly.

 

2.

Excess-flow check valve

2.

Close propane supply valve on

 

 

closed.

 

propane tank and reopen

 

 

 

 

slowly.

 

3.

Air in gas line.

3.

Allow several minutes to purge

 

 

 

 

air with automatic control

 

 

 

 

valve button depressed.

 

4.

Blockage in pilot orifice.

4.

Replace pilot orifice.

 

5.

Piezo ignition system not

5.

Adjust ignitor electrode gap to

 

 

sparking.

 

.120". Check wire lead for

 

 

 

 

damage. Replace piezo ignitor

 

 

 

 

and/or ignitor electrode as

 

 

 

 

necessary.

 

 

 

 

 

Pilot lights

1.

Not enough warm-up time.

1.

Relight, hold automatic control

but goes

 

 

 

valve button in 45 seconds.

out when

2. Low gas pressure.

2.

Check propane tank(s) for

automatic

 

 

 

proper gas supply.

control valve

3. Thermocouple loose or

3.

Tighten connection or replace

button

 

needs to be replaced.

 

thermocouple.

is released.

4.

Automatic control valve

4.

Replace automatic control

 

 

needs to be replaced.

 

valve.

 

 

 

 

Maximum

1. Main burner valve not fully

1.

Fully open main burner valve

burn rate

 

open.

 

by turning the valve handle

is low.

 

 

 

towards ON position until it

 

 

 

 

stops.

 

2.

Plugged gas orifices.

2.

Replace gas orifice.

 

3.

Low gas pressure.

3.

Check gas supply; check

 

 

 

 

regulator output.

 

4.

Low fuel supply.

4.

Consult propane gas supplier.

 

 

 

 

Soot forming

1. Main burner valve not open

1.

Adjust main burner valve

inside heater,

 

enough.

 

slowly towards ON position

flame 100%

 

 

 

until flame has more blue

yellow.

 

 

 

color.

 

2.

Low fuel supply.

2.

Consult propane gas supplier.

101283

9

Image 9
Contents Propane Construction Heater Contents SafetyInformation Safety Information Unpacking ProductTheory OperationPropane SupplyVentilation Regulator With Vent Pointing Down InstallationTo Start Heater Storage MaintenanceTo Stop Heater To Restart HeaterSymptom Possible Cause Remedy Trouble ShootingReplacement Parts AccessoriesParts Under Warranty Parts Not Under WarrantyKEY VMH10TN Description QTY Parts ListKeep this Warranty Limited Warranty Warranty and Repair Service