Desa TC200V, RCP200V owner manual Ventilation, Installation, Operation, To Start Heater

Page 4

4

VENTILATION INSTALLATION OPERATION

VENTILATION

WARNING: Provide at least a 6 square foot open-

Fuel Gas Fitting

ing of fresh, outside air while running heater. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.

Supply Valve

Hose

Regulator

FRESH OUTSIDE AIR OPENING REQUIREMENTS

HEATER SIZE

SQ. FT. OPENING

200,000 Btu/Hr

6.0

INSTALLATION

Vent

(pointing down)

Propane Tank

Figure 2 - Regulator With Vent Pointing Down

WARNING: Review and understand the warnings in the Safety Information section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.

WARNING: Test all gas piping and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

1.Provide propane supply system (see Propane Supply, page 3).

2.Connect fuel gas fitting on hose/regulator assembly to pro- pane tank(s). Turn fuel gas fitting counterclockwise into threads on tank. Tighten firmly using a wrench. IMPORTANT: Tighten regulator with vent pointing down. Pointing vent down pro- tects regulator from weather damage.

3.Connect hose to the valve inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater even if pro- pane tank has one.

4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, you may hear a click inside the regulator assembly, this is the check valve closing. To re- set the excess-flow check valve, close propane supply valve and open it again slowly.

5.Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected.

6.Close propane supply valve.

Valve Inlet

AT

LO

PUSH

TO START

 

HI

Hose

Figure 3 - Hose and Valve Inlet

OPERATION

WARNING: Review and understand the warnings in the Safety Information section on pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.

TO START HEATER

1.Follow all installation, ventilation, and safety information.

2.Locate heater on stable and level surface. Make sure strong drafts do not blow on heater.

3.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, you may hear a click inside the regulator assembly, this is the check valve closing. To re- set the excess-flow check valve, close propane supply valve and open it again slowly.

4.Turn control knob clockwise to the lowest position and push in (see Figure 4, page 5).

5.With the control knob pushed all the way in, press and release the piezo ignitor button (see Figure 4, page 5). Keep pressing piezo ignitor button until the burner lights. Hold control knob down for a maximum of 10 seconds while attempting ignition. If heater does not ignite, release control knob and wait 3 min- utes before attempting reignition.

Note: Keep hands and face away from outlet (around top of shell) of heater while attempting to start heater.

For morevisit www..com

103886-01F

Image 4
Contents Propane TM Construction Heater Table of Contents Safety InformationSafety Information Product Identification UnpackingTheory of Operation Propane SupplyInstallation VentilationOperation To Start HeaterReplacement Parts MaintenanceStorage Specifications TroubleshootingAccessories Symptom Possible Cause RemedyIllustrated Parts Breakdown and Parts List KEY Part Description QTYWarranty Service Repair Service

RCP200V, TC200V specifications

The Desa TC200V and RCP200V represent a new wave of innovative solutions in the landscape of heating technology. These models, designed to address both residential and commercial heating needs, come equipped with a range of features and characteristics that set them apart from traditional heating options.

Starting with the Desa TC200V, this high-efficiency unit is engineered to provide optimal heat output while minimizing energy consumption. One of the standout features is its advanced combustion technology, which maximizes fuel efficiency. By utilizing a dual-fuel capability, the TC200V offers users the flexibility to choose between natural gas and propane. This versatility not only enhances convenience but also ensures that users can adapt to varying availability and pricing of fuel sources.

The TC200V’s design incorporates a durable outer casing, ensuring longevity and resistance to wear and tear. Additionally, its user-friendly control panel allows for seamless operation, enabling users to easily set their desired temperature and monitor performance. Enhanced safety features, including an automatic shut-off mechanism and flame failure device, provide peace of mind, ensuring secure and reliable operation.

On the other hand, the RCP200V complements the TC200V with its innovative radiant heating technology. This model targets heat distribution more efficiently through the use of infrared radiation. It heats objects and individuals in the room directly, creating a comfortable atmosphere without the need to excessively warm the ambient air. This not only leads to enhanced comfort but also contributes to energy savings, as less energy is wasted on heating unoccupied spaces.

The RCP200V is also equipped with a smart thermostat, allowing for programmable heating schedules, further optimizing energy usage. Its lightweight construction ensures easy installation, making it a suitable choice for both new constructions and retrofitting projects. Moreover, the sleek design enhances the aesthetic appeal of any space, making it a perfect addition to modern interiors.

Collectively, the Desa TC200V and RCP200V embody cutting-edge advancements in heating technology. By combining efficiency, versatility, and safety, they cater to a diverse array of heating requirements, establishing themselves as formidable players in the heating market. Whether it’s a cozy home environment or a commercial space needing reliable heating, these models provide a compelling solution that meets the modern consumer's needs for both comfort and efficiency.