Desa TC200V, RCP200V Specifications, Troubleshooting, Accessories, Symptom Possible Cause Remedy

Page 6

6

SPECIFICATIONS TROUBLESHOOTING ACCESSORIES

SPECIFICATIONS

Rating (BTU/Hr)

High - 200,000

 

Low - 100,000

Fuel

Propane Vapor Only

Fuel Consumption

Gallons/Hour - 1.09min./2.19 max.

 

Pounds/Hour - 4.64min./9.28 max.

Supply Pressure (To Regulator)

Maximum - 200 psi Minimum - 20 psi (for input adjustment)

Manifold Pressure

High - 4.6 psi

 

Low - 5.9 psi

Weight (lbs)

16

Shipping Weight (lbs)

20

Size - L x W x H (in.)

30 x 15 x 16

Minimum Temp.

-20°F (-29°C) Surrounding Air

TROUBLESHOOTING

You may have further questions about this heater. If so, contact DESA International’s Technical Service Department at 1-866-672-6040.

ACCESSORIES

Purchase these accessories and parts from your local dealer or service center. If your dealer or service center can not supply an accessory or part, contact your nearest Parts Central (listed in the separate Authorized Service Center booklet) or call DESA Interna- tional at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

Part Number

Description

LPA1020

10' Rubber Hose with Brass Fitting

 

U.L. listed.

LPA2005

Propane Gas Regulator

 

U.L. listed.

LPA3005

Hose/Regulator Assembly

 

U.L. listed.

LPA4020

Fuel Gas Connector

 

Connects regulator to all standard

 

propane tanks. U.L. and A.G.A. listed.

WARNING: Never attempt to service heater while it is connected to propane supply, operating, or hot. Severe burns can occur.

SYMPTOM

POSSIBLE CAUSE

REMEDY

Burner fails to light

1.

Propane supply valve closed on propane

1.

Open propane supply valve slowly

 

 

tank(s)

 

 

 

2.

Excess-flow check valve closed

2.

Close propane supply valve on propane

 

 

 

 

tank and reopen slowly

 

3.

Blockage in burner nozzle

3.

Replace burner nozzle

 

4.

Piezo ignition system not sparking

4.

Check to assure ignitor electrode gap is

 

 

 

 

.130". Check wire lead for damage. Re-

 

 

 

 

place piezo ignitor and/or ignitor elec-

 

 

 

 

trode as necessary

 

 

 

 

 

Burner lights but goes out when automatic

1.

Not enough warm-up time

1.

Relight, hold automatic control valve

control valve button is released

 

 

 

button in 45 seconds

 

2.

Low gas pressure

2.

Check propane tank(s) for proper gas

 

 

 

 

supply

 

3.

Thermocouple loose or needs to be re-

3.

Tighten connection or replace thermo-

 

 

placed

 

couple

 

4.

Automatic control valve needs to be re-

4.

Replace automatic control valve

 

 

placed

 

 

 

 

 

 

 

Burn rate is low

1.

Main burner valve not fully open

1.

Fully open main burner valve by turn-

 

 

 

 

ing control knob towards HIGH posi-

 

 

 

 

tion until it stops

 

2.

Plugged gas orifices

2.

Replace gas orifice

 

3.

Low gas pressure

3.

Check gas supply; check regulator output

 

4.

Low fuel supply

4.

Consult propane gas supplier

For more

 

visit www.

 

.com

103886-01F

Image 6
Contents Propane TM Construction Heater Table of Contents Safety InformationTheory of Operation Safety Information Product IdentificationUnpacking Propane SupplyOperation InstallationVentilation To Start HeaterMaintenance Replacement PartsStorage Accessories SpecificationsTroubleshooting Symptom Possible Cause RemedyIllustrated Parts Breakdown and Parts List KEY Part Description QTYWarranty Service Repair Service

RCP200V, TC200V specifications

The Desa TC200V and RCP200V represent a new wave of innovative solutions in the landscape of heating technology. These models, designed to address both residential and commercial heating needs, come equipped with a range of features and characteristics that set them apart from traditional heating options.

Starting with the Desa TC200V, this high-efficiency unit is engineered to provide optimal heat output while minimizing energy consumption. One of the standout features is its advanced combustion technology, which maximizes fuel efficiency. By utilizing a dual-fuel capability, the TC200V offers users the flexibility to choose between natural gas and propane. This versatility not only enhances convenience but also ensures that users can adapt to varying availability and pricing of fuel sources.

The TC200V’s design incorporates a durable outer casing, ensuring longevity and resistance to wear and tear. Additionally, its user-friendly control panel allows for seamless operation, enabling users to easily set their desired temperature and monitor performance. Enhanced safety features, including an automatic shut-off mechanism and flame failure device, provide peace of mind, ensuring secure and reliable operation.

On the other hand, the RCP200V complements the TC200V with its innovative radiant heating technology. This model targets heat distribution more efficiently through the use of infrared radiation. It heats objects and individuals in the room directly, creating a comfortable atmosphere without the need to excessively warm the ambient air. This not only leads to enhanced comfort but also contributes to energy savings, as less energy is wasted on heating unoccupied spaces.

The RCP200V is also equipped with a smart thermostat, allowing for programmable heating schedules, further optimizing energy usage. Its lightweight construction ensures easy installation, making it a suitable choice for both new constructions and retrofitting projects. Moreover, the sleek design enhances the aesthetic appeal of any space, making it a perfect addition to modern interiors.

Collectively, the Desa TC200V and RCP200V embody cutting-edge advancements in heating technology. By combining efficiency, versatility, and safety, they cater to a diverse array of heating requirements, establishing themselves as formidable players in the heating market. Whether it’s a cozy home environment or a commercial space needing reliable heating, these models provide a compelling solution that meets the modern consumer's needs for both comfort and efficiency.