Desa CGB3930NR, CGB3924NR Volt Battery Installation, Pressure Testing Heater Gas Connections

Page 12

CGD3924NR, CGB3924NR and CGB3930NR

UVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Fig- ure 13).

2.Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to manual shutoff valve (see Figure 14). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Manual

Open

Shutoff

 

Valve

 

Closed

Pressure Testing Heater Gas Connections

1.Open manual shutoff valve (see Fig- ure 13).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 14). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 15 through 17). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 16).

9-VOLT BATTERY INSTALLATION

Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Alkaline Battery In Receiver

1.Locate back of receiver under front burner of heater.

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt alkaline battery through the clip.

4.Attach the teminal wires to the battery.

Receiver

Figure 13 - Manual Shutoff Valve

Manual

Thermostat Gas Valve or

Shutoff

Control Valve Location

Valve

 

Gas Meter

Figure 14 - Checking Gas Joints

Terminal

Wires

9-Volt Battery

Figure 15 - Installing 9-Volt Battery In Receiver

Installing 9-Volt Battery In Hand- Held Remote Control Unit

1.Remove battery cover on back of re- mote control unit.

2.Attack terminal wires to the battery. Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery Cover

Remote

Control

Terminal

Unit

 

Wires

 

9-Volt

 

Battery

 

Battery

Housing

Figure 16 - Installing Battery In Hand-

Held Remote control Unit

12

104306

Image 12
Contents Yellow Flame Model Shown What to do if YOU Smell GASSafety Information Product Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation InstallationLOG Sizing Requirements Check GAS TypeIf Not Using Mantel If Using MantelMinimum Non-Combustible Material Clearances Mantel Clearances Floor ClearancesInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply Pressure Testing gas Supply Piping systemChecking GAS Connections Test Pressures In Excess Of 1/2 PsigVolt Battery Installation Pressure Testing Heater Gas ConnectionsInstalling 9-Volt Alkaline Battery In Receiver Installing 9-Volt Battery In Hand- Held Remote Control UnitInstalling Logs CGD3924NR Place the base of the middle log #2Installing Logs on Models CGB3924PR and CGB3930PR Installing Back Log #2For Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Hand Held Remote OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atSpecificationsaccessories Wiring DiagramTechnical Service Service HintsIllustrated Parts Breakdown CGD3924NRParts List KEY Part Number Description QTYCGB3924NR CGB3930NR KEY CGB3924NR CGB3930NR Part Number Description QTY Replacement Parts Parts Under WarrantyParts not Under Warranty Parts Central104306 Warranty Information