Desa CGB3930NR, CGB3924NR installation manual Top, Gas leak. See Warning statement at

Page 20

CGD3924NR, CGB3924NR and CGB3930NR

UVENTED NATURAL GAS LOG HEATER

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Open window and ventilate room. Stop using odor causing products while heater is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 17)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 12)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

20

104306

Image 20
Contents Yellow Flame Model Shown What to do if YOU Smell GASSafety Information Product Features Product IdentificationLocal Codes UnpackingAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined Space and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation InstallationLOG Sizing Requirements Check GAS TypeMinimum Non-Combustible Material Clearances If Not Using MantelIf Using Mantel Mantel Clearances Floor ClearancesInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply Pressure Testing gas Supply Piping systemChecking GAS Connections Test Pressures In Excess Of 1/2 PsigVolt Battery Installation Pressure Testing Heater Gas ConnectionsInstalling 9-Volt Alkaline Battery In Receiver Installing 9-Volt Battery In Hand- Held Remote Control UnitInstalling Logs CGD3924NR Place the base of the middle log #2Installing Logs on Models CGB3924PR and CGB3930PR Installing Back Log #2Lighting Instructions For Your Safety Read Before LightingOperating Heater Manual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Hand Held Remote OperationCleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atSpecificationsaccessories Wiring DiagramTechnical Service Service HintsIllustrated Parts Breakdown CGD3924NRParts List KEY Part Number Description QTYCGB3924NR CGB3930NR KEY CGB3924NR CGB3930NR Part Number Description QTY Replacement Parts Parts Under WarrantyParts not Under Warranty Parts Central104306 Warranty Information