Desa CGD3930N, CGD3018N Local Codes Unpacking Product Features, Operation, Safety Device

Page 4

PRODUCT IDENTIFICATION

LOCAL CODES

UNPACKING

PRODUCT

FEATURES

4

Crossover Log

Back Log

Front Log

 

Burner

Piezo

Middle Log

Ignitor

 

 

Control Knob

 

Base Grate

Figure 1 - Vent-Free Gas Log Heater

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.

*Available from: American National Standards Institute, Inc. 1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

Operation

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. You can operate heater as a vented product by opening flue damper.

Safety Device

This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

102990

Image 4
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Burner patterns can cause sooting Local Codes Unpacking Product Features Safety DeviceOperation Piezo Ignition SystemVentilation AIR forProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Check GAS TypeLOG Sizing Requirements Minimum Fireplace ClearanceMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances Installing Minimum Non Combustible Material Clearances Log SetFloor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededMounting Bracket Connecting to GAS Supply Checking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Installing LogsFor Your Safety Read Before Lighting Operating HeaterOperating HeaterManual Lighting Procedure Control Knob Ignitor Button Pilot Flame Pattern Inspecting BurnersThermostat-Controlled Models Only Cleaning MaintenanceTrouble Shooting ODS/PILOT and BurnerMaintenance, TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Optional Optional Positioning of Thermostat Sensing Bulb Service Hints Technical ServiceModel Models Parts Not Under Warranty Parts Under WarrantyParts Central Accessories Valve GA5010Hood GA6050 Hood GA6052Illustrated Parts Breakdown Parts List CGD3018N CGD3924N CGD3930NCGD3924NT CGD3924NT 102990 102990 Warranty Information Keep this Warranty

CGD3018N, CGD3930N specifications

The Desa CGD3930N and CGD3018N are innovative gas heaters that exemplify cutting-edge technology and design in the heating industry. Both models are designed to provide efficient heating solutions for residential spaces, ensuring comfort during colder months while being environmentally conscious.

The CGD3930N is a powerful unit featuring a heating capacity of up to 30,000 BTUs, making it suitable for larger areas. It combines radiant and convection heating methods to ensure even heat distribution throughout the space. This model is equipped with a thermostat for precise temperature control, allowing users to set their desired comfort level easily. One of its standout features is the built-in oxygen depletion sensor, which enhances safety by monitoring the air quality to prevent hazardous conditions.

On the other hand, the CGD3018N, with a heating capacity of 18,000 BTUs, is perfect for smaller rooms or spaces that require consistent heating without excessive energy consumption. Its compact design makes it adaptable for various room layouts. Like the CGD3930N, it also features an adjustable thermostat, ensuring users can maintain the preferred level of warmth. The heater's flameless design provides a safe alternative to traditional heating methods, reducing the risk of accidents.

Both models utilize advanced ceramic burner technology, which enhances combustion efficiency and reduces emissions. This is particularly important as households increasingly seek to minimize their environmental footprint. This technology also ensures that both heaters operate quietly, providing warmth without the disruption of noisy mechanisms.

A significant aspect of the Desa CGD3930N and CGD3018N is their versatility. They can be installed as wall-mounted units or freestanding options, giving homeowners the flexibility to choose the best configuration for their space. The modern aesthetic of both models complements a wide range of interior designs, making them not only functional but stylish additions to any home.

In conclusion, the Desa CGD3930N and CGD3018N are excellent choices for those seeking reliable and efficient heating solutions. With their advanced features, safety measures, and stylish designs, these gas heaters provide warmth and comfort in any residential environment while promoting energy efficiency.