INSTALLING

Continued

10

NOTICE

You may use this heater as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fire- place opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.

Minimum Non Combustible Material Clearances

If Not Using Mantel

Note: If using a mantel, go to page 11. If not using a mantel, follow the informa- tion on this page.

You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8" up (for all models). If non combus- tible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See chart below and Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

 

 

 

12" or more

Non combustible material okay.

Between 8" and 12"

24" or 30" Models: Install fireplace hood acessory

 

(GA6050 or GA6052, see Accessories, page 33).

 

18" Model: Non combustible material okay.

Less than 8"

Non combustible material must be extended to at

 

least 8". See Between 8" and 12", above. If you

 

cannot extend material, you must operate heater

 

with flue damper open.

 

 

 

Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

102990

Image 10
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Burner patterns can cause sooting Operation Local Codes Unpacking Product FeaturesSafety Device Piezo Ignition SystemVentilation AIR forProviding Adequate Ventilation Determining AIR Flow for Heater Location AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Check GAS TypeLOG Sizing Requirements Minimum Fireplace ClearanceMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances Installing Minimum Non Combustible Material Clearances Log SetFloor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededMounting Bracket Connecting to GAS Supply Checking GAS Connections Gas ConnectionPressure Testing Heater Gas Connections Test Pressures Equal To or Less Than 1/2 PsigInstalling Installing LogsFor Your Safety Read Before Lighting Operating HeaterOperating HeaterManual Lighting Procedure Control Knob Ignitor Button Pilot Flame Pattern Inspecting BurnersThermostat-Controlled Models Only Trouble Shooting CleaningMaintenance ODS/PILOT and BurnerMaintenance, TROUBLE- ShootingRefer to Air for Com Gas leak. See Warning Optional Optional Positioning of Thermostat Sensing Bulb Service Hints Technical ServiceModel Models Parts Not Under Warranty Parts Under WarrantyParts Central Hood GA6050 AccessoriesValve GA5010 Hood GA6052Illustrated Parts Breakdown Parts List CGD3018N CGD3924N CGD3930NCGD3924NT CGD3924NT 102990 102990 Warranty Information Keep this Warranty

CGD3018N, CGD3930N specifications

The Desa CGD3930N and CGD3018N are innovative gas heaters that exemplify cutting-edge technology and design in the heating industry. Both models are designed to provide efficient heating solutions for residential spaces, ensuring comfort during colder months while being environmentally conscious.

The CGD3930N is a powerful unit featuring a heating capacity of up to 30,000 BTUs, making it suitable for larger areas. It combines radiant and convection heating methods to ensure even heat distribution throughout the space. This model is equipped with a thermostat for precise temperature control, allowing users to set their desired comfort level easily. One of its standout features is the built-in oxygen depletion sensor, which enhances safety by monitoring the air quality to prevent hazardous conditions.

On the other hand, the CGD3018N, with a heating capacity of 18,000 BTUs, is perfect for smaller rooms or spaces that require consistent heating without excessive energy consumption. Its compact design makes it adaptable for various room layouts. Like the CGD3930N, it also features an adjustable thermostat, ensuring users can maintain the preferred level of warmth. The heater's flameless design provides a safe alternative to traditional heating methods, reducing the risk of accidents.

Both models utilize advanced ceramic burner technology, which enhances combustion efficiency and reduces emissions. This is particularly important as households increasingly seek to minimize their environmental footprint. This technology also ensures that both heaters operate quietly, providing warmth without the disruption of noisy mechanisms.

A significant aspect of the Desa CGD3930N and CGD3018N is their versatility. They can be installed as wall-mounted units or freestanding options, giving homeowners the flexibility to choose the best configuration for their space. The modern aesthetic of both models complements a wide range of interior designs, making them not only functional but stylish additions to any home.

In conclusion, the Desa CGD3930N and CGD3018N are excellent choices for those seeking reliable and efficient heating solutions. With their advanced features, safety measures, and stylish designs, these gas heaters provide warmth and comfort in any residential environment while promoting energy efficiency.