Desa BLUE FLAME VENT-FREE NATURAL GAS HEATER Specifications, Replacement Parts, Technical Service

Page 15

OWNER’S MANUAL

SPECIFICATIONS

 

VN600B/CFN600B

Btu (Variable)

4,400/6,000

Type Gas

Natural Only

Ignition

Piezo

Pressure Regulator Setting

3" W.C.

Inlet Gas Pressure (inches of water)

 

 

Maximum

10.5"

Minimum

4"

 

Dimensions, Inches (H x W x D)

 

 

Heater (including knobs and grill)

21

1/2 x 13 1/2 x 7

Carton

24

3/4 x 16 3/4 x 7 1/2

Weight (pounds)

 

 

Heater

13.5

Shipping

19

 

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealer from whom you purchased this product. If they cannot sup- ply original replacement part(s), call DESA International’s Technical Service Depart- ment at 1-800-323-5190 for referral infor- mation.

When contacting your dealer or DESA In- ternational, have ready:

your name

your address

model number of your heater

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

how heater was malfunctioning

type of gas used (propane or natural

 

gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

Parts Not Under Warranty

SERVICE HINTS

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

ACCESSORY

Purchase this heater accessory from your local dealer. If they cannot supply this ac- cessory, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.

MANUAL SHUTOFF

VALVE - GA5010

Manual shutoff valve with 1/8" NPT tap.

Contact authorized dealers of this product. If they cannot supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready:

model number of your heater

the replacement part number

103113

15

Image 15
Contents BTU Manually Controlled Models Blue Flame VENT-FREE Natural GAS HeaterVanguard 6000 BTU Natural GAS Heater Safety InformationLocal Codes Product FeaturesProduct AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Wall Installing toPlacing Heater On Mounting Screws Installing to WallInstalling Bottom Mounting Screw Attaching to wall anchor methodMinim um Connecting to GAS SupplyChecking GAS Connections Pressure Testing GAS Supply Piping SystemPressure Testing Heater GAS Connections For Your Safety Read Before LightingShutting Off Heater Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Trouble ShootingGas leak. See Warning statement at top Service Publications SpecificationsReplacement Parts Technical ServiceIllustrated Parts List Models VN600B and CFN600B Vanguard 6000 BTU Natural GAS Heater 103113 Limited Warranty VENT-FREE Residential GAS Heaters Warranty Information