Desa BLUE FLAME VENT-FREE NATURAL GAS HEATER installation manual Models VN600B and CFN600B

Page 17

OWNER’S MANUAL

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual.

MODELS: VN600B and CFN600B

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

 

 

 

 

1

098304-01

Screw, #10 x 3/8"

2

2

099467-03

Front Panel Assembly (VN600B)

1

 

099467-04

Front Panel Assembly (CFN600B)

1

3

099318-04

Grill Guard

1

4

101108-01

Grill Guard Clip

2

5

102018-01AA

Bottom Glass Retainer

1

6

098260-03

Glass Panel

1

7

098532-03AA

Top Glass Retainer

1

8

M11084-38

Screw, #8 x 3/8"

8

9

098352-03BR

Deflector Unit

1

10

098271-03

Ignitor Cable

1

11

098249-01

Nut, M5

2

12

100701-03

ODS/Pilot Assembly

1

12-1

098514-01

Thermocouple

1

12-2

098594-01

Ignitor Electrode

1

13

099386-02

Burner

1

14

099387-05

Pilot Tubing

1

15

098251-01

Injector

1

16

099463-01

Injector Holder

1

17

099415-01

Pressure Regulator

1

18

099462-01

Burner Tubing

1

19

099391-02

Regulator Tubing

1

20

098276-01

1/8" NPT Plug

1

21

099057-01

Pressure Tap Fitting

1

22

099413-01

Control Valve

1

23

099468-06

Cabinet

1

24

102445-01

Piezo Ignitor

1

25

099393-01

Control Knob

1

26

098508-01

Valve Retainer Nut

1

27

098303-02

Screw, #6 x 5/16"

2

28

099553-01

Pilot Shield

1

29

099818-01

Internal Tooth Washer

1

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

099395-09

100642-02

Control Position Label Assembly, Hardware

1

1

103113

17

Image 17
Contents BTU Manually Controlled Models Blue Flame VENT-FREE Natural GAS HeaterVanguard 6000 BTU Natural GAS Heater Safety InformationProduct Product FeaturesAIR for Combustion and Ventilation Local CodesUnusually Tight Construction Determining AIR Flow for Heater LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Wall Installing toInstalling Bottom Mounting Screw Installing to WallAttaching to wall anchor method Placing Heater On Mounting ScrewsMinim um Connecting to GAS SupplyPressure Testing Heater GAS Connections Pressure Testing GAS Supply Piping SystemFor Your Safety Read Before Lighting Checking GAS ConnectionsLighting Instructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Trouble ShootingGas leak. See Warning statement at top Replacement Parts SpecificationsTechnical Service Service PublicationsIllustrated Parts List Models VN600B and CFN600B Vanguard 6000 BTU Natural GAS Heater 103113 Limited Warranty VENT-FREE Residential GAS Heaters Warranty Information