Desa BLUE FLAME VENT-FREE NATURAL GAS HEATER Connecting to GAS Supply, Minim um

Page 8

VANGUARD 6000 BTU

NATURAL GAS HEATER

CONNECTING TO GAS SUPPLY

NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

IMPORTANT: Check gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe 3/8" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be up- stream from heater (see Figure 12).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap (trap) in supply line as shown in Figure 12. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps mois- ture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/ or fittings.

 

Pressure

 

Regulator

3/8" NPT

 

 

 

Pipe Nipple

 

 

 

 

Heater

 

 

Cabinet

 

Ground Joint Union

 

 

 

Manual

Tee Joint

 

 

 

 

 

Shutoff

Reducer

 

 

Valve *

 

Test

Bushing to

 

From

 

Gauge

1/8" NPT

 

 

Connection *

External

 

 

 

 

 

Regulator

1/8" NPT

 

 

(4" W.C. to

Plug Tap

 

 

10.5" W.C.

 

 

 

Pressure)

Tee

 

 

 

 

 

3" Minimum

Joint

 

 

 

Sediment Trap

 

Pipe

 

 

 

 

Nipple

 

 

Cap

*An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessory, page 15.

Figure 12 - Gas Connection

8

103113

Image 8
Contents Blue Flame VENT-FREE Natural GAS Heater BTU Manually Controlled ModelsSafety Information Vanguard 6000 BTU Natural GAS HeaterProduct Features ProductAIR for Combustion and Ventilation Local CodesDetermining AIR Flow for Heater Location Unusually Tight ConstructionConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing to WallInstalling to Wall Installing Bottom Mounting ScrewAttaching to wall anchor method Placing Heater On Mounting ScrewsConnecting to GAS Supply Minim umPressure Testing GAS Supply Piping System Pressure Testing Heater GAS ConnectionsFor Your Safety Read Before Lighting Checking GAS ConnectionsManual Lighting Procedure Lighting InstructionsTo Turn OFF GAS To Appliance Shutting Off HeaterCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyTrouble Shooting Maintenance,Gas leak. See Warning statement at top Specifications Replacement PartsTechnical Service Service PublicationsIllustrated Parts List Models VN600B and CFN600B Vanguard 6000 BTU Natural GAS Heater 103113 Warranty Information Limited Warranty VENT-FREE Residential GAS Heaters