Desa LDL3924NR Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 15

OPERATING HEATER

For Your Safety Read Before Lighting Lighting Instructions

15

OPERATING HEATER

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fire- place will cause glass to burst. Make sure there are no obstructions across opening of fireplace.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the highest heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

WARNING: Burners will come on automatically within one minute when the control valve is in the ON position after the pilot is lit.

1.STOP! Read the safety information in column 1.

2.Make sure equipment shutoff valve is fully open.

3.Remove control cover log (see Figure 26).

4.Set remote selector switch in the AUTO position (see Figure 25).

5.Press in and turn control knob clockwise to the OFF position (see Figure 25).

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

7.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 25).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

 

Control Knob

Remote

Ignitor

Selector

Button

Switch

 

AUTO

MAN

Figure 25 - Remote Selector Switch, Control Knob and Ignitor Button

Control

Knob

 

O

 

F

N

F

O

TO LI

 

Control Cover Log

Ignitor

 

Button

Figure 26 - Control Knob (Shown in the OFF Positon) and Ignitor

Button Location

For morevisit www..com

111515-01A

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation Installation ManualSafety Information Table of ContentsUnpacking Local CodesProduct Features Product IdentificationAIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeLOG Sizing Requirements Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededInstalling Battery into Remote Installing Batteries in ReceiverSure regulator Connecting to GAS SupplyPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Rear Log Log #1 Placement Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Shutting Off Heater Manual Lighting ProcedureHAND-HELD Remote Operation To Turn OFF GAS To ApplianceMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Models LDL3924NR, LDL3924PR LDL3930NR and LDL3930PR Illustrated Parts BreakdownParts List Technical Service SpecificationsReplacement Parts Wiring Diagram Service HintsOwners Registration Form Postage Required Accessories Warranty Information

LDL3924NR specifications

Desa LDL3924NR is a state-of-the-art model that embodies innovative technology and advanced features aimed at providing optimal performance in its class. This model is particularly designed for users who demand reliability and efficiency in their operations.

One of the standout features of the Desa LDL3924NR is its high-performance engine. Designed to deliver excellent power output, this engine ensures that operations are smooth and efficient, making it suitable for a variety of tasks. The power-to-weight ratio is optimized, which provides the user with enhanced control and responsiveness, ensuring that even the most demanding applications can be tackled with ease.

The design of the Desa LDL3924NR incorporates advanced materials, which not only contribute to its durability but also help in reducing maintenance requirements. This characteristic is particularly beneficial for users who prioritize longevity and reliability in their equipment. Moreover, the ergonomic design ensures that the model is user-friendly, allowing operators of varying skill levels to handle it with confidence.

In terms of technology, the Desa LDL3924NR is equipped with a sophisticated control system that monitors performance metrics in real time. This technology provides users with insights into efficiency and operational status, empowering them to make informed decisions that can enhance productivity. Additionally, the model is designed with safety features that prioritize operator well-being, minimizing risks and ensuring compliance with industry standards.

Another key characteristic of the Desa LDL3924NR is its versatility. It performs reliably across different settings, whether in industrial, agricultural, or commercial environments. This multifunctionality makes it an attractive option for a diverse range of users.

In conclusion, the Desa LDL3924NR stands out due to its powerful engine, durable construction, innovative technology, and safety features. Its versatility allows it to adapt to various applications, making it an indispensable tool for professionals seeking efficiency and reliability. With its commitment to quality and performance, the Desa LDL3924NR is poised to meet the growing demands of users across multiple sectors.