Desa LDL3924NR installation manual Local Codes, Unpacking

Page 3

SAFETY INFORMATION LOCAL CODES UNPACKING

3

SAFETY INFORMATION

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Lo- cate propane/LP supply tank(s) outdoors (propane/LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom, unless installed as a vented appliance. See Installing Damper Clamp Accessory for Vented Operation, page 10.

5.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ig- nite if highly heated. Inspect chimney flue for damage. If dam- aged, repair flue before operating heater.

6.Do not burn solid-fuel in a masonry or UL127 factory-built fireplace in which a vent-free room heater is installed.

7.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across opening of fireplace.

8.To prevent the creation of soot, follow the instructions in Clean- ing and Maintenance, page 18.

9.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod- ucts may create a white powder residue within burner box or on adjacent walls and furniture.

10.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if enough fresh air is not available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 19 through 21.

11.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not use this heater to cook food or burn paper or other objects.

13.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room heater and to replace any part of the control system and any gas control which has been under water.

14.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger).

15.Turn heater off and let cool before servicing, installing, or re- pairing. Only a qualified service person should install, service, or repair heater.

16.Operating heater above elevations of 4,500 feet may cause pi- lot outage.

17.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity (propane/LP units only).

18.Provide adequate clearances around air openings.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

UNPACKING

CAUTION: Do not remove the data plates from the grate assembly. The data plates contain important warranty and safety information.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could dam- age heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

For morevisit www..com

111515-01A

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation Installation ManualSafety Information Table of ContentsUnpacking Local CodesProduct Features Product IdentificationAIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeLOG Sizing Requirements Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededInstalling Battery into Remote Installing Batteries in ReceiverSure regulator Connecting to GAS SupplyPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Rear Log Log #1 Placement Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Shutting Off Heater Manual Lighting ProcedureHAND-HELD Remote Operation To Turn OFF GAS To ApplianceMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Models LDL3924NR, LDL3924PR LDL3930NR and LDL3930PR Illustrated Parts BreakdownParts List Technical Service SpecificationsReplacement Parts Wiring Diagram Service HintsOwners Registration Form Postage Required Accessories Warranty Information

LDL3924NR specifications

Desa LDL3924NR is a state-of-the-art model that embodies innovative technology and advanced features aimed at providing optimal performance in its class. This model is particularly designed for users who demand reliability and efficiency in their operations.

One of the standout features of the Desa LDL3924NR is its high-performance engine. Designed to deliver excellent power output, this engine ensures that operations are smooth and efficient, making it suitable for a variety of tasks. The power-to-weight ratio is optimized, which provides the user with enhanced control and responsiveness, ensuring that even the most demanding applications can be tackled with ease.

The design of the Desa LDL3924NR incorporates advanced materials, which not only contribute to its durability but also help in reducing maintenance requirements. This characteristic is particularly beneficial for users who prioritize longevity and reliability in their equipment. Moreover, the ergonomic design ensures that the model is user-friendly, allowing operators of varying skill levels to handle it with confidence.

In terms of technology, the Desa LDL3924NR is equipped with a sophisticated control system that monitors performance metrics in real time. This technology provides users with insights into efficiency and operational status, empowering them to make informed decisions that can enhance productivity. Additionally, the model is designed with safety features that prioritize operator well-being, minimizing risks and ensuring compliance with industry standards.

Another key characteristic of the Desa LDL3924NR is its versatility. It performs reliably across different settings, whether in industrial, agricultural, or commercial environments. This multifunctionality makes it an attractive option for a diverse range of users.

In conclusion, the Desa LDL3924NR stands out due to its powerful engine, durable construction, innovative technology, and safety features. Its versatility allows it to adapt to various applications, making it an indispensable tool for professionals seeking efficiency and reliability. With its commitment to quality and performance, the Desa LDL3924NR is poised to meet the growing demands of users across multiple sectors.