Desa VFP24MV, VFP18MV, VFP30MV installation manual Installing Logs, Installing Front Log #1

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

INSTALLING LOGS

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place front logs (#1L and #1R) on top of the grate. Make sure the notches in the bottom of the logs fit over the grate prongs (see Figure 17). Push back of logs flush with metal grate bar. Note: 18" model has only one front log.

2.Rest bottom middle log (#2) behind metal posts on front burner. Make sure the grooves in the bottom of the log fit over the grate. Bring the log forward next to the metal posts. The pegs on the log must be on top (see Figure 18).

3.Slide the grooves in the back of the rear log (#3) against the rear grate prongs. Make sure the peg on the log is on top (see Figure 19).

4.Place the top middle log (#4) on the bottom middle log (#2). Make sure the pegs of the bottom middle log fit se- curely in the holes of the top middle log (see Figure 20).

5.Place the crossover log (#5) on the back log and the top middle log. Make sure the peg on the rear log is in the hole in the bottom of the crossover log. The crossover log should fit in the cutout of the top middle log (see Figure 21).

Front Log (#1)

Notch

Grate

Prongs

Metal Grate Bar

Figure 17 - Installing Front Log (#1)

Bottom Middle

Log (#2)

Groove

Groove

Metal

Post

Metal Post Grate

Figure 18 - Installing Bottom Middle Log (#2)

Peg

Rear Log (#3)

Groove in

Groove

in Back

Back of Log

of Log

 

Grate Prong

 

Grate

Prong

Figure 19 - Installing Rear Log (#3)

Hole

Top Middle

 

Log (#4)

Peg

Figure 20 - Installing Crossover Log (#4)

Crossover

Log (#5)

Hole

Cutout

Peg

Figure 21 - Installing Crossover Log (#5)

105071

13

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Local Codes Product FeaturesUnpacking Product IdentificationProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Clearances InstallationCheck GAS Type Vent-Free Operation OnlyMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Front Log #1 Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions Inspecting Burners Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement VFP18MV VFP24MV VFP30MV Illustrated Parts BreakdownKEY Part Number for VFP18MV VFP24MV VFP30MV Description QTY Parts ListService Hints SpecificationsTechnical Service Accessories105071 Warranty Information