Desa VFP24MV, VFP18MV, VFP30MV installation manual OWNER’S Operation and Installation Manual

Page 1

UNVENTED (VENT-FREE)

PROPANE/LP GAS LOG HEATER

ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE

OWNER’S OPERATION AND INSTALLATION MANUAL

VFP18MV

VFP24MV

VFP30MV

 

LO

 

PILOT

Variable Manually-

OFF

HI

Controlled

EMBER MASTER

 

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per- sonal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjust- ment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installa- tion and operational procedures. For as- sistance or additional information con- sult a qualified installer, service agency, or the gas supplier.

WARNING: This appliance is for installa- tion only in a solid-fuel burning masonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design- certified for these installations in accor- dance with ANS Z21.11.2. Exception: Do not install this appliance in a factory- built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Local Codes Product FeaturesUnpacking Product IdentificationProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Clearances InstallationCheck GAS Type Vent-Free Operation OnlyMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Front Log #1 Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions Inspecting Burners Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement VFP18MV VFP24MV VFP30MV Illustrated Parts BreakdownKEY Part Number for VFP18MV VFP24MV VFP30MV Description QTY Parts ListService Hints SpecificationsTechnical Service Accessories105071 Warranty Information