Desa VFP24MV Specifications, Service Hints, Technical Service, Accessories, Replacement Parts

Page 22

FIREPLACE MANUFACTURERS INC.

UNVENTED PROPANE/LP GAS LOG HEATER

SPECIFICATIONS

 

18" Variable

 

Manually-

 

Controlled

Btu (Variable)

16,000/26,000

Type Gas

Propane/LP Only

Ignition

Piezo

Manifold Pressure

7.9" W.C.

Inlet Gas

Pressure (in. of water)

Maximum 14"

Minimum* 11"

Shipping Weight

26 lbs.

* For purpose of input adjustment

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burners will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

TECHNICAL

SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact Fireplace Manufacturers Incorporated’s Technical Service Depart- ment at 1-888-427-8322.

You can also visit DESA International’s technical service web site at www.desatech.com.

24" Variable

30" Variable

Manually-

Manually-

Controlled

Controlled

20,000/33,000

21,500/36,000

Propane/LP Only

Propane/LP Only

Piezo

Piezo

7.9" W.C.

7.9" W.C.

14"

14"

11"

11"

30 lbs.

34 lbs.

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call Fireplace Manufacturers Incorporated’s Parts Department at 1-800- 888-2050 for referral information. You can also write to the address listed on the back page of this manual.

FIREPLACE HOOD

Black - HDABK (Part # 01244) Brass - HDABR (Part # 01245)

For all models. Helps deflect heat away from mantel or wall above fireplace. Fits openings 28" to 49" wide.

DAMPER CLAMP - 02017

(Not Shown)

For manually-controlled models. Perma- nently opens chimney flue damper for vented operation.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated’s Technical Service Depart- ment at 1-888-427-8322.

When calling Fireplace Manufacturers Incorporated, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated’s Parts Department at 1-800- 888-2050 for referral information.

When calling Fireplace Manufacturers Incorporated, have ready

model number of your heater

the replacement part number

LAVA ROCK - GA6060

(Not Shown)

For all models. Order when additional rock is desired. (31/2 lb. bag)

22

105071

Image 22
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unpacking Product FeaturesLocal Codes Product IdentificationUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationInstallation Clearances Vent-Free Operation OnlyIf Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Connecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Installing Front Log #1Operating Heater For Your Safety Read Before LightingLighting Instructions Inspecting Burners Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Illustrated Parts Breakdown VFP18MV VFP24MV VFP30MVParts List KEY Part Number for VFP18MV VFP24MV VFP30MV Description QTYTechnical Service SpecificationsService Hints Accessories105071 Warranty Information