Desa VGP30 installation manual Turn counterclockwise

Page 14
C-clockwise
C-clockwise
C-clockwise

14

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 13. If you don’t smell gas, go to the next step.

5. Press in control knob and turn counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 14).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The burner and pilot are located behind the heat shield. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to TROUBLESHOOTING, pages 17 thru

20.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see MANUAL LIGHTING PROCEDURE, page 15.

Ignitor Electrode

Thermocouple

Pilot Burner

Pilot

GRH/OV 007F

 

Figure 15 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 sec- onds, release control knob.

Note: If pilot goes out, repeat steps 3 thru 7.

8. Turn control knob counterclockwise to the LOW position. The main burner should light. Set control knob to any heat level between HIGH and LOW. To turn control knob from LOW to a higher setting, press in the control knob

and turn counterclockwise .

Note: Both HIGH and LOW are locked positions. You must press in control knob before turning it from these positions.

!CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

Continued

Image 14
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Locating Heater Installation ItemsCheck GAS Type Surface Combustible MaterialRemoving Front Panel Of Heater Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallMarking Screw Locations Attaching Mounting Bracket To WallInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing GAS Supply Piping System Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveLighting Instructions For Your Safety Read Before LightingOperating Heater Turn counterclockwise To Turn OFF GAS to Appliance Manual Lighting ProcedureInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Air PassagewaysCleaning From Ing statement at TopTechnical Service Service HintsParts Not Under Warranty Replacement PartsParts Under Warranty Accessories Valve GA5010ODS/Pilot Parts List KEY Part Number Description QTYPage Page Warranty Information International