!WARNING
If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
OBSERVED | POSSIBLE |
|
PROBLEM | CAUSE | REMEDY |
|
|
|
Heater produces a | 1. Metal expanding while | 1. This is common with |
clicking/ticking noise | heating or contracting | most heaters. If noise is |
just after burner is lit or | while cooling | excessive, contact quali- |
shut off |
| fied service person |
Heater produces un- | 1. | Heater burning vapors |
wanted odors |
| from paint, solvents, |
|
| glues, etc. |
| 2. | Low fuel supply |
| 3. | Gas leak. See Warn- |
|
| ing statement at |
|
| top of page |
1.Ventilate garage. Stop using odor causing prod- ucts while heater is run- ning
2.Refill supply tank
3.Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 11)
Heater shuts off in use | 1. | Not enough fresh air is |
(ODS operates) |
| available |
| 2. | Low line pressure |
| 3. | ODS/pilot is partially |
|
| clogged |
1.Open window and/or door for ventilation
2.Contact local propane gas company
3.Clean ODS/pilot (see
CLEANING AND MAINTENANCE, page 17)
Gas odor even when | 1. | Gas leak. See Warn- | 1. | Locate and correct all |
control knob is in OFF |
| ing statement at |
| leaks (see CHECKING |
position |
| top of page |
| GAS CONNECTIONS, |
|
|
|
| page 11) |
| 2. | Control valve defective | 2. | Replace control valve |
|
|
|
|
|
20
Gas odor during com- | 1. | Foreign matter between |
bustion |
| control valve and |
|
| burner |
| 2. | Gas leak. See Warn- |
|
| ing statement at |
|
| top of page |
1.Take apart gas tubing and remove foreign mat- ter
2.Locate and correct all leaks (see CHECKING GAS CONNECTIONS, page 11)