OBSERVED | POSSIBLE |
|
|
|
|
|
|
| |||
PROBLEM | CAUSE |
|
| REMEDY |
|
|
| ||||
|
|
|
|
|
| ||||||
Burner does not light | 2. | Burner orifice diameter | 2. | Replace burner orifice |
| ||||||
after ODS/pilot is lit |
| is too small |
|
|
|
|
|
|
| ||
(continued from | 3. | Inlet gas pressure is too | 3. | Contact local propane gas | |||||||
page 18) |
| low |
|
|
| company |
|
|
| ||
|
|
|
|
| |||||||
Delayed ignition of | 1. | Manifold pressure is too | 1. | Contact local propane gas | |||||||
burner |
|
| low |
|
|
| company |
|
|
| |
|
| 2. | Burner | orifice | is | 2. | Clean | burner | (see | ||
|
|
| clogged |
|
| CLEANING |
| AND | |||
|
|
|
|
|
|
| MAINTENANCE, page | ||||
|
|
|
|
|
|
| 17) or replace burner ori- | ||||
|
|
|
|
|
|
| fice |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Burner backfiring | 1. | Burner | orifice | is | 1. | Clean | burner | (see | |||
during combustion |
| clogged or damaged |
|
| CLEANING |
| AND | ||||
|
|
|
|
|
|
| MAINTENANCE, page | ||||
|
|
|
|
|
|
| 17) or replace burner ori- | ||||
|
|
|
|
|
|
| fice |
|
|
|
|
|
| 2. | Burner damaged |
| 2. | Replace burner |
|
|
| ||
|
| 3. | Gas regulator defective | 3. | Replace gas regulator |
| |||||
|
|
|
|
|
|
| |||||
Yellow | flame during | 1. | Not enough air |
| 1. | Check burner for dirt and | |||||
burner combustion |
|
|
|
|
| debris. If found, | clean | ||||
|
|
|
|
|
|
| burner (see CLEANING | ||||
|
|
|
|
|
|
| AND MAINTENANCE, | ||||
|
|
|
|
|
|
| page 17) |
|
|
| |
|
| 2. | Gas regulator defective | 2. | Replace gas regulator |
| |||||
|
|
|
|
| |||||||
Slight smoke or odor | 1. | Residues from manu- | 1. | Problem will stop after a | |||||||
during | initial opera- |
| facturing processes |
|
| few hours of operation | |||||
tion |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Heater | produces a | 1. | Turning control knob to | 1. | Turn | control | knob | to | |||
whistling noise when |
| HIGH | position when |
| LOW | position | and | let | |||
burner is lit |
| burner is cold |
|
| warm up for a minute |
| |||||
|
| 2. | Air in gas line |
| 2. | Operate burner until air is | |||||
|
|
|
|
|
|
| removed from line. Have | ||||
|
|
|
|
|
|
| gas line checked by local | ||||
|
|
|
|
|
|
| propane gas company |
| |||
|
| 3. | Air passageways | on | 3. | Observe minimum instal- | |||||
|
|
| heater blocked |
|
| lation | clearances | (see | |||
|
|
|
|
|
|
| Figure 2, page 6) |
|
| ||
|
| 4. | Dirty | or partially | 4. | Clean | burner | (see | |||
|
|
| clogged burner orifice |
| CLEANING |
| AND | ||||
|
|
|
|
|
|
| MAINTENANCE, page |
17) or replace burner ori- fice
19