INSPECTING BURNER
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater |
| to the PILOT position. | |
1. | Turn control knob clockwise | Clockwise | |
2. | Press in control knob and turn clockwise Clockwise to the OFF position. | ||
3. | Turn off all electric power to the appliance if service is to be performed. |
Shutting Off Burner Only (pilot stays lit)
1. Turn control knob clockwise Clockwise to the PILOT position.
MANUAL LIGHTING PROCEDURE
1.Remove front panel (see Figure 3, page 7).
2.Follow steps 1 thru 5 under LIGHTING INSTRUCTIONS, pages 13 and 14.
3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
5.Replace front panel.
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
Figure 16 shows a correct pilot flame pattern. Figure 17 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Thermocouple | Pilot Burner |
|
Figure 16 - Correct Pilot Flame Pattern
Thermocouple | Pilot Burner |
|
Figure 17 - Incorrect Pilot Flame Pattern
Continued 15