Desa VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA installation manual

Page 11

INSTALLATION

Built-In Fireplace Installation (Cont.)

11

INSTALLATION

Continued

1.Frame in rough opening. Use dimensions shown in Figure 16 for the rough opening.

2.If using blower, install wiring and properly ground the three- prong, 120 volt electrical outlet in fireplace.

3.Before replacing bottom of firebox, install duplex outlet to the right support bracket in the bottom of firebox (see Figure 17).

4.Route wires from electrical box through smallest hole in outer casing using strain relief fitting provided (see Figure 17).

5.Connect wires from the electrical box to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to con- nect ground wire.

6.Install shield to end of right support bracket and behind the firebox wrapper with 2 screws provided (see Figure 18).

7.Plug blower cord into duplex outlet. Note: On thermostat model fireplaces, route power cord to the back of the fireplace to clear thermostat valve.

8.Replace bottom of firebox.

9.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, pages 12 and 13.

10.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

11.Attach flexible gas line to gas supply. See Connecting Fire- place to Gas Supply, pages 13 and 14.

12.Plug electrical cord into electrical outlet installed in step 2.

13.Carefully insert fireplace into rough opening.

14.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 19).

15.Check all gas connections for leaks. See Checking Gas Con- nections, pages 14 and 15.

16.Install brass trim after final finishing and/or painting of wall (see Figure 7, page 8).

17 3/4"

33"

35 1/2"

Figure 16 - Rough Opening for Installing in Wall

 

Cable from

 

Electrical

 

Source

Blower

Duplex

 

Outlet

Blower

Strain

Power

Cord

Relief

 

Fitting

 

Support

 

Bracket

 

Screw

Figure 17 - Connecting Duplex Outlet

Support Bracket

Firebox

Wrapper

Shield

Power Screws

Cord

Figure 18 - Attaching Fireplace to Wall Studs (FPVF33PRA Shown)

Nails or

Wood

Screws

Nailing Flanges

Figure 19 - Attaching Fireplace to Wall Studs (FPVF33PRA Shown)

For morevisit www..com

110148-01A

Image 11
Contents What to do if YOU Smell GAS Qqqq ¢¢¢¢Safety Information Table of ContentsOther gases Product IdentificationAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Electrical Hookup InstallationInstalling Hood Check GAS TypeAssembling and Attaching Optional Brass Trim Installation ClearancesIncluded with Mantel Accessory Placing Hearth Base Accessory Against Wall Conventional Fireplace InstallationActual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Installation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Gas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Installing LogsFPVF33PRA Installing 9-Volt Battery in Receiver Optional Wireless HAND-HELD RemoteInstalling 9-VOLT Batteries Installing Remote Receiver UnitLighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Ghrc Series Operation Inspecting BurnersOptional Blower Operation Pilot Flame PatternMain Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesLogs Wiring DiagramSpecifications Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement VYGF33PRB Illustrated Parts BreakdownKEY Part Number VYGF33PRB VYGF33NRB Description QTY Parts ListFirebox VYGF33PRB VYGF33NRB KEY Part Number Description QTY Firebox VYGF33PRB & VYGF33NRBFPVF33PRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox FPVF33PRA FPVF33NRA Firebox FPVF33PRA & FPVF33NRA Accessories Firebox Perimeter Brass Trim Accessory GA6090 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Parts Under Warranty Replacement PartsTechnical Service Service HintsOwners Registration Form Postage Required 110148-01A Warranty Information

VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA, VYGF33NRB, VYGF33PRB specifications

Desa VYGF33NRB, VYGF33PRB, and FPVF33PRA are leading models in the domain of innovative heating solutions, featuring state-of-the-art technology and design aimed at efficiency and performance. These heating units are engineered to cater to a variety of spaces while ensuring user-friendly operation and environmental considerations.

The VYGF33NRB and VYGF33PRB models are distinguished by their advanced radiant heating technology. They utilize infrared heat, which warms objects and surfaces directly rather than simply heating the air. This method proves to be highly efficient, particularly in large or poorly insulated spaces, as it minimizes energy waste and promotes rapid heating.

Both VYGF33NRB and VYGF33PRB models come equipped with adjustable thermostats, allowing users to maintain precise temperature controls according to their specific needs. This feature complements the energy-saving capabilities of these models, ensuring that they only operate when necessary, thereby reducing overall energy consumption. Furthermore, the sleek, modern design of these models makes them an attractive addition to any indoor or outdoor setting.

The FPVF33PRA and FPVF33NRA, on the other hand, focus on versatility and portability. With lighter designs and built-in mobility features, these units can be easily relocated according to the user's requirements. They incorporate integrated safety mechanisms, such as tip-over switches and overheat protection, ensuring that safety remains a priority even in dynamic environments.

In addition to their heating capabilities, these models are equipped with air filtration technologies that improve indoor air quality. This feature is particularly beneficial in regions where allergens and pollutants can affect health and comfort. The air filtration systems in the FPVF33 series transform heating units into multi-functional appliances, providing not just warmth but also clean air.

Another noteworthy characteristic is the ease of maintenance that these units offer. Many components are designed for easy access, allowing for routine cleaning and replacement to ensure longevity. These models also feature energy-efficient settings that adapt to environmental conditions, making them suitable for various climates.

In conclusion, the Desa VYGF33NRB, VYGF33PRB, FPVF33PRA, and FPVF33NRA models epitomize the merging of innovative technology with practical utility. Their distinct features such as energy efficiency, advanced heating technology, portability, and air filtration capabilities cater to a wide range of heating needs while promoting a safer, healthier living environment. With these models, users can expect not only comfort but also a commitment to sustainability in their heating solutions.