Desa VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA installation manual

Page 16

16

INSTALLATION

Installing Logs

INSTALLATION

Continued

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with fireplace.

1.For models VYGF33PRB and VYGF33NRB, place one-piece log set on grate to fit as illustrated in Figure 28. For models FPVF33PRA and FPVF33NRA, place one-piece log set on grate to fit as illustrated in Figure 29. Make sure middle sec- tion at bottom of log set is seated into "U"-shaped cutout in center of chassis (see Figure 29). IMPORTANT: Make sure log does not cover any burner ports (see Figures 30 and 31).

2.Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 32).

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is in place before running fireplace.

One Piece

 

Log Set

Middle

 

Section at

 

Bottom of

 

Log Set

 

Burner

Chassis

"U"-shaped

 

 

Cutout in

 

Chassis

Figure 28 - Installing One Piece Log Set (Models VYGF33NRB & VYGF33PRB)

One

Piece

Log Set

Middle Section

at Bottom of

Log Set

 

One Piece

Burner Ports

Log Set

Figure 30 - Installing One Piece Log Set (Top View Models VYGF33NRB & VYGF33PRB)

 

One Piece

Burner Ports

Log Set

 

Figure 31 - Installing One Piece Log Set (Top View Models FPVF33NRA & FPVF33PRA)

Notches

Screws for

Mounting Screen

Figure 32 - Installing Fireplace Screen (Model VYGF33NRB shown)

Chassis

Burner

"U"-shaped Cutout in Chassis

Figure 29 - Installing One Piece Log Set (Models FPVF33NRA &

FPVF33PRA)

For..com

110148-01A

Image 16
Contents Qqqq ¢¢¢¢ What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Other gasesProduct Features Local CodesUnpacking AIR for Combustion and VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Installing HoodCheck GAS Type Electrical HookupIncluded with Mantel Accessory Installation ClearancesAssembling and Attaching Optional Brass Trim Conventional Fireplace Installation Placing Hearth Base Accessory Against WallActual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS Supply Gas ConnectionPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Fireplace Gas ConnectionsFPVF33PRA Optional Wireless HAND-HELD Remote Installing 9-VOLT BatteriesInstalling Remote Receiver Unit Installing 9-Volt Battery in ReceiverOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureOptional Remote Operation Inspecting Burners Optional Blower OperationPilot Flame Pattern Ghrc Series OperationCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleBurner Primary AIR Holes Main BurnerSpecifications Wiring DiagramLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Illustrated Parts Breakdown VYGF33PRBParts List KEY Part Number VYGF33PRB VYGF33NRB Description QTYFirebox VYGF33PRB VYGF33NRB Firebox VYGF33PRB & VYGF33NRB KEY Part Number Description QTYFPVF33PRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox FPVF33PRA FPVF33NRA Firebox FPVF33PRA & FPVF33NRA Accessories Receiver and HAND-HELD Remote Control KIT Ghrc Series WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Firebox Perimeter Brass Trim Accessory GA6090Replacement Parts Technical ServiceService Hints Parts Under WarrantyOwners Registration Form Postage Required 110148-01A Warranty Information

VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA, VYGF33NRB, VYGF33PRB specifications

Desa VYGF33NRB, VYGF33PRB, and FPVF33PRA are leading models in the domain of innovative heating solutions, featuring state-of-the-art technology and design aimed at efficiency and performance. These heating units are engineered to cater to a variety of spaces while ensuring user-friendly operation and environmental considerations.

The VYGF33NRB and VYGF33PRB models are distinguished by their advanced radiant heating technology. They utilize infrared heat, which warms objects and surfaces directly rather than simply heating the air. This method proves to be highly efficient, particularly in large or poorly insulated spaces, as it minimizes energy waste and promotes rapid heating.

Both VYGF33NRB and VYGF33PRB models come equipped with adjustable thermostats, allowing users to maintain precise temperature controls according to their specific needs. This feature complements the energy-saving capabilities of these models, ensuring that they only operate when necessary, thereby reducing overall energy consumption. Furthermore, the sleek, modern design of these models makes them an attractive addition to any indoor or outdoor setting.

The FPVF33PRA and FPVF33NRA, on the other hand, focus on versatility and portability. With lighter designs and built-in mobility features, these units can be easily relocated according to the user's requirements. They incorporate integrated safety mechanisms, such as tip-over switches and overheat protection, ensuring that safety remains a priority even in dynamic environments.

In addition to their heating capabilities, these models are equipped with air filtration technologies that improve indoor air quality. This feature is particularly beneficial in regions where allergens and pollutants can affect health and comfort. The air filtration systems in the FPVF33 series transform heating units into multi-functional appliances, providing not just warmth but also clean air.

Another noteworthy characteristic is the ease of maintenance that these units offer. Many components are designed for easy access, allowing for routine cleaning and replacement to ensure longevity. These models also feature energy-efficient settings that adapt to environmental conditions, making them suitable for various climates.

In conclusion, the Desa VYGF33NRB, VYGF33PRB, FPVF33PRA, and FPVF33NRA models epitomize the merging of innovative technology with practical utility. Their distinct features such as energy efficiency, advanced heating technology, portability, and air filtration capabilities cater to a wide range of heating needs while promoting a safer, healthier living environment. With these models, users can expect not only comfort but also a commitment to sustainability in their heating solutions.