Desa VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA Optional Wireless HAND-HELD Remote

Page 17

INSTALLATION

Optional Wireless Hand-Held Remote Control Accessories Installing 9-Volt Batteries

17

INSTALLATION

Continued

OPTIONAL WIRELESS HAND-HELD REMOTE

CONTROL ACCESSORIES (GHRC and

GHRCTA Series)

Installing Remote Receiver Unit

1.Disconnect switch wires from the control valve.

2.Remove screws attaching switchplate.

3.Remove switch plate (see Figure 33). Discard after removing.

4.Install remote receiver unit onto gas log heater base using mounting clips.

5.Push clips firmly into place (see Figure 34).

6.Connect wires as shown in Figure 35.

INSTALLING 9-VOLT BATTERIES

Two 9-volt batteries (not included) are required to operate this heater with the wireless hand held remote control set. Install one battery in the receiver and one in the hand-held remote control unit. Note: Only use alkaline batteries.

Installing 9-Volt Battery in Receiver

1.Locate back of receiver under front burner of heater.

2.Locate the battery clip mounted on the back of the receiver.

3.Slide a 9-volt battery through the clip.

4.Attach the terminal wires to the battery.

Remote

Switch

Bracket

Screw

Ignitor

Remote

Terminal

Receiver

 

Wires

Battery Clip

Switch Plate

Wires

Figure 33 - Switch Plate and Wiring Harness

Mounting

Clips

Remote Receiver

Figure 34 - Installing Remote Receiver

White Wire

From

Receiver

Valve

Red Wire From

Receiver

Figure 35 - Connecting Wires

9-Volt Battery

Figure 36 - Installing Battery in Remote Receiver

Installing 9-Volt Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote control unit.

2.Attach terminal wires to the battery. Place battery into the bat- tery housing.

3.Replace battery cover onto remote control unit.

 

Model

Battery

 

Terminal

GHRC

 

Cover

Remote

 

Wires

 

 

Control Unit

 

 

 

Model

 

 

 

GHRCTA

9-VoltBattery

BatteryHousing

Figure 37 - Installing Battery in Hand-Held Remote Control Unit

For morevisit www..com

110148-01A

Image 17
Contents What to do if YOU Smell GAS Qqqq ¢¢¢¢Safety Information Table of ContentsOther gases Product IdentificationLocal Codes Product FeaturesUnpacking AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing Hood InstallationCheck GAS Type Electrical HookupAssembling and Attaching Optional Brass Trim Installation ClearancesIncluded with Mantel Accessory Placing Hearth Base Accessory Against Wall Conventional Fireplace InstallationActual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Installation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Gas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Installing LogsFPVF33PRA Installing 9-VOLT Batteries Optional Wireless HAND-HELD RemoteInstalling Remote Receiver Unit Installing 9-Volt Battery in ReceiverLighting Instructions For Your Safety Read Before LightingOperating Fireplace Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Optional Blower Operation Inspecting BurnersPilot Flame Pattern Ghrc Series OperationCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceBurner Primary AIR Holes Main BurnerLogs Wiring DiagramSpecifications Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement VYGF33PRB Illustrated Parts BreakdownKEY Part Number VYGF33PRB VYGF33NRB Description QTY Parts ListFirebox VYGF33PRB VYGF33NRB KEY Part Number Description QTY Firebox VYGF33PRB & VYGF33NRBFPVF33PRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox FPVF33PRA FPVF33NRA Firebox FPVF33PRA & FPVF33NRA Accessories WALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT ON/OFF Switch GWMS2 Firebox Perimeter Brass Trim Accessory GA6090Technical Service Replacement PartsService Hints Parts Under WarrantyOwners Registration Form Postage Required 110148-01A Warranty Information

VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA, VYGF33NRB, VYGF33PRB specifications

Desa VYGF33NRB, VYGF33PRB, and FPVF33PRA are leading models in the domain of innovative heating solutions, featuring state-of-the-art technology and design aimed at efficiency and performance. These heating units are engineered to cater to a variety of spaces while ensuring user-friendly operation and environmental considerations.

The VYGF33NRB and VYGF33PRB models are distinguished by their advanced radiant heating technology. They utilize infrared heat, which warms objects and surfaces directly rather than simply heating the air. This method proves to be highly efficient, particularly in large or poorly insulated spaces, as it minimizes energy waste and promotes rapid heating.

Both VYGF33NRB and VYGF33PRB models come equipped with adjustable thermostats, allowing users to maintain precise temperature controls according to their specific needs. This feature complements the energy-saving capabilities of these models, ensuring that they only operate when necessary, thereby reducing overall energy consumption. Furthermore, the sleek, modern design of these models makes them an attractive addition to any indoor or outdoor setting.

The FPVF33PRA and FPVF33NRA, on the other hand, focus on versatility and portability. With lighter designs and built-in mobility features, these units can be easily relocated according to the user's requirements. They incorporate integrated safety mechanisms, such as tip-over switches and overheat protection, ensuring that safety remains a priority even in dynamic environments.

In addition to their heating capabilities, these models are equipped with air filtration technologies that improve indoor air quality. This feature is particularly beneficial in regions where allergens and pollutants can affect health and comfort. The air filtration systems in the FPVF33 series transform heating units into multi-functional appliances, providing not just warmth but also clean air.

Another noteworthy characteristic is the ease of maintenance that these units offer. Many components are designed for easy access, allowing for routine cleaning and replacement to ensure longevity. These models also feature energy-efficient settings that adapt to environmental conditions, making them suitable for various climates.

In conclusion, the Desa VYGF33NRB, VYGF33PRB, FPVF33PRA, and FPVF33NRA models epitomize the merging of innovative technology with practical utility. Their distinct features such as energy efficiency, advanced heating technology, portability, and air filtration capabilities cater to a wide range of heating needs while promoting a safer, healthier living environment. With these models, users can expect not only comfort but also a commitment to sustainability in their heating solutions.