Desa VYGF33PRB, VYGF33NRB Installation, Check GAS Type, Electrical Hookup, Installing Hood

Page 7

INSTALLATION

Check Gas Type

Electrical Hookup

Installing Hood

7

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in- stall fireplace. Follow all local codes.

WARNING: Never install the fireplace

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flam- mable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This fireplace creates warm air cur- rents. These currents move heat to wall surfaces next to fireplace. Installing fireplace next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited, to tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.

Use the dimensions shown for rough openings to create the easiest installation. See Built-In Fireplace Installation, pages 10 and 11.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

IMPORTANT: Make sure the fireplace is level. If fireplace is not level, log set will not work properly.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your fireplace. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

ELECTRICAL HOOKUP

(Models GA3700 Series and GA3700T Series

Blower Accessories, and GA3555 Internal

Duplex Kit)

This fireplace accepts a blower assembly with an electrical cord. The electrical cord is five feet in length. You must locate fireplace within reach of a 120 volt grounded electrical outlet. If not, you must install an electrical outlet within reach of fireplace power cord. The GA3555 outlet accessory is used for built-in applications with blower accessory installed.

INSTALLING HOOD

Install hood to top of firebox as shown in Figure 5. Use 3 Phillips screws provided.

Figure 5 - Installing Hood to Firebox

For morevisit www..com

110148-01A

Image 7
Contents What to do if YOU Smell GAS Qqqq ¢¢¢¢Safety Information Table of ContentsOther gases Product IdentificationAIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined and Unconfined Space Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeIncluded with Mantel Accessory Installation ClearancesAssembling and Attaching Optional Brass Trim Placing Hearth Base Accessory Against Wall Conventional Fireplace InstallationActual Framing Height Front Width 34 5 35 1 Depth 16 11 17 3 Support Bracket Firebox Wrapper Shield Power Screws Cord Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Gas Connection Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Installing LogsFPVF33PRA Installing 9-Volt Battery in Receiver Optional Wireless HAND-HELD RemoteInstalling 9-VOLT Batteries Installing Remote Receiver UnitOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureOptional Remote Operation Ghrc Series Operation Inspecting BurnersOptional Blower Operation Pilot Flame PatternMain Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesSpecifications Wiring DiagramLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement VYGF33PRB Illustrated Parts BreakdownKEY Part Number VYGF33PRB VYGF33NRB Description QTY Parts ListFirebox VYGF33PRB VYGF33NRB KEY Part Number Description QTY Firebox VYGF33PRB & VYGF33NRBFPVF33PRA KEY Part Number FPVF33PRA FPVF33NRA Description QTY Firebox FPVF33PRA FPVF33NRA Firebox FPVF33PRA & FPVF33NRA Accessories Firebox Perimeter Brass Trim Accessory GA6090 Receiver and HAND-HELD Remote Control KIT Ghrc SeriesWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Parts Under Warranty Replacement PartsTechnical Service Service HintsOwners Registration Form Postage Required 110148-01A Warranty Information

VYGF33PRB, VYGF33NRB, FPVF33PRA, FPVF33NRA, VYGF33NRB, VYGF33PRB specifications

Desa VYGF33NRB, VYGF33PRB, and FPVF33PRA are leading models in the domain of innovative heating solutions, featuring state-of-the-art technology and design aimed at efficiency and performance. These heating units are engineered to cater to a variety of spaces while ensuring user-friendly operation and environmental considerations.

The VYGF33NRB and VYGF33PRB models are distinguished by their advanced radiant heating technology. They utilize infrared heat, which warms objects and surfaces directly rather than simply heating the air. This method proves to be highly efficient, particularly in large or poorly insulated spaces, as it minimizes energy waste and promotes rapid heating.

Both VYGF33NRB and VYGF33PRB models come equipped with adjustable thermostats, allowing users to maintain precise temperature controls according to their specific needs. This feature complements the energy-saving capabilities of these models, ensuring that they only operate when necessary, thereby reducing overall energy consumption. Furthermore, the sleek, modern design of these models makes them an attractive addition to any indoor or outdoor setting.

The FPVF33PRA and FPVF33NRA, on the other hand, focus on versatility and portability. With lighter designs and built-in mobility features, these units can be easily relocated according to the user's requirements. They incorporate integrated safety mechanisms, such as tip-over switches and overheat protection, ensuring that safety remains a priority even in dynamic environments.

In addition to their heating capabilities, these models are equipped with air filtration technologies that improve indoor air quality. This feature is particularly beneficial in regions where allergens and pollutants can affect health and comfort. The air filtration systems in the FPVF33 series transform heating units into multi-functional appliances, providing not just warmth but also clean air.

Another noteworthy characteristic is the ease of maintenance that these units offer. Many components are designed for easy access, allowing for routine cleaning and replacement to ensure longevity. These models also feature energy-efficient settings that adapt to environmental conditions, making them suitable for various climates.

In conclusion, the Desa VYGF33NRB, VYGF33PRB, FPVF33PRA, and FPVF33NRA models epitomize the merging of innovative technology with practical utility. Their distinct features such as energy efficiency, advanced heating technology, portability, and air filtration capabilities cater to a wide range of heating needs while promoting a safer, healthier living environment. With these models, users can expect not only comfort but also a commitment to sustainability in their heating solutions.