Desa VYM27NR installation manual Connecting to GAS Supply, Attaching Flexible Gas Hose to Heater

Page 11

OWNER’S MANUAL

INSTALLATION

Continued

7.Mark screw locations through one hole on each side of the mounting flanges (see Figure 12). If installing in a brick- bottom fireplace, mark screw locations in mortar joint of bricks.

8.Remove heater base from fireplace.

9.Drill holes at marked locations using 3/16" drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package).

11.Connect to gas supply. See Connect- ing To Gas Supply, page 11.

12.Replace logs on heater base.

Flexible Gas Fitting Hose (if allowed

by local codes)

Figure 11 - Attaching Flexible Gas Hose to Heater

Masonry Screw

Mounting

Flanges

Figure 12 - Attaching Base Assembly to Fireplace Floor

CONNECTING TO GAS

SUPPLY

NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to LP gas)

manual shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 24.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Approved Flexible Gas Hose (if allowed by local codes)

Gas Control

Figure 13 - Gas Connection

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

CAUTION: Avoid damage to control. Hold gas fitting with wrench when connecting it to gas piping and/or fittings.

A.G.A. Design-Certified

Manual Shutoff Valve With

1/8" NPT Tap*

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

Tee

 

Joint

 

3" Minimum

Sediment

Pipe

Trap

Nipple

Cap

 

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 24.

** Minimum inlet pressure for purpose of input adjustment.

Continued

 

 

104674

11

Image 11
Contents Patent Pending OWNER’S Operation and Installation ManualRemote Control Ready Model What to do if YOU Smell GASVanguard Flame MAX Unvented Natural GAS LOG Heater Safety InformationLocal Codes Product FeaturesRemote Control Accessories Product IdentificationConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingMinimum Fireplace Clearance to Combustible Materials InstallationInstallation Clearances Check GAS TypeMinimum Noncombustible Material Clearances If Not Using MantelIf Using Mantel Determining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesChimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Checking GAS ConnectionsInstalling Bottom Log #1 Installing LogsInstructions For Your Safety Read Before LightingOperating Heater Optional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Main Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesObserved Problem Possible Cause TroubleshootingMaintenance, Observed Problem Possible Cause RemedyGas leak. See Warning statement at top TopTechnical Service Wiring Diagram Replacement PartsSpecifications Service HintsLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole VYM27NR Illustrated Parts BreakdownDescription QTY Parts ListAccessories 104674 International Limited Warranty VENT-FREE Natural GAS LOG Heaters

VYM27NR specifications

Desa VYM27NR is a cutting-edge piece of technology designed to meet the demanding needs of modern users while ensuring energy efficiency and superior performance. This innovative device integrates advanced features and smart technologies that make it a popular choice among professionals and consumers alike.

One of the main features of the Desa VYM27NR is its robust performance powered by a high-efficiency motor. This motor is capable of delivering exceptional power output while minimizing energy consumption, which contributes to lower operational costs. The unit operates quietly, making it suitable for use in residential areas without causing disruption.

In addition to its powerful motor, the Desa VYM27NR is equipped with smart sensors that automatically adjust performance based on user requirements. This intelligent adjustment ensures optimal operation, resulting in enhanced user experience. The device also includes an intuitive control panel that allows users to easily monitor and manage settings, further simplifying its use.

Another noteworthy characteristic of the Desa VYM27NR is its compact and lightweight design. This portability allows users to easily move it between different locations or store it without taking up much space. It is constructed from durable materials that ensure longevity and reliability, making it a sound investment for any user.

The technology behind Desa VYM27NR also includes enhanced safety features. It is equipped with multiple safety sensors that provide protection against overheating and electrical surges, ensuring the device operates within safe parameters at all times.

Furthermore, the Desa VYM27NR boasts environmental responsibility with its eco-friendly operating capabilities. It adheres to stringent regulations regarding emissions and energy use, thus aligning with global efforts towards sustainability.

In summary, the Desa VYM27NR showcases a blend of powerful performance, user-friendly features, and safety technologies. Its compact design, efficient energy use, and eco-friendly attributes make it stand out in the market, appealing to a diverse range of users who seek efficiency and reliability in their devices. Whether for personal or professional use, the Desa VYM27NR promises to deliver exceptional performance and value, making it a top choice in its category.