Desa VYM27NR Cleaning and Maintenance, Cleaning Burner Injector Holder and Pilot AIR Inlet Hole

Page 21

OWNER’S MANUAL

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 26).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 27). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Burner

Injector Holder

(May Be Brass

Tube

or Aluminum

 

Depending on

 

Model)

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Figure 26 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 13, to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

Figure 27 - Pilot Inlet Air Hole

104674

21

Image 21
Contents Remote Control Ready Model OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Patent PendingVanguard Flame MAX Unvented Natural GAS LOG Heater Safety InformationRemote Control Accessories Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Not Using Mantel If Using MantelMinimum Noncombustible Material Clearances Mantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Chimney Minimum Permanent Height ft Flue Opening sq. insAttaching Flexible Gas Hose to Heater Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Bottom Log #1 Installing LogsFor Your Safety Read Before Lighting Operating HeaterInstructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Pilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerObserved Problem Possible Cause TroubleshootingMaintenance, Observed Problem Possible Cause RemedyGas leak. See Warning statement at top TopSpecifications Wiring Diagram Replacement PartsService Hints Technical ServiceCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs VYM27NR Illustrated Parts BreakdownDescription QTY Parts ListAccessories 104674 International Limited Warranty VENT-FREE Natural GAS LOG Heaters

VYM27NR specifications

Desa VYM27NR is a cutting-edge piece of technology designed to meet the demanding needs of modern users while ensuring energy efficiency and superior performance. This innovative device integrates advanced features and smart technologies that make it a popular choice among professionals and consumers alike.

One of the main features of the Desa VYM27NR is its robust performance powered by a high-efficiency motor. This motor is capable of delivering exceptional power output while minimizing energy consumption, which contributes to lower operational costs. The unit operates quietly, making it suitable for use in residential areas without causing disruption.

In addition to its powerful motor, the Desa VYM27NR is equipped with smart sensors that automatically adjust performance based on user requirements. This intelligent adjustment ensures optimal operation, resulting in enhanced user experience. The device also includes an intuitive control panel that allows users to easily monitor and manage settings, further simplifying its use.

Another noteworthy characteristic of the Desa VYM27NR is its compact and lightweight design. This portability allows users to easily move it between different locations or store it without taking up much space. It is constructed from durable materials that ensure longevity and reliability, making it a sound investment for any user.

The technology behind Desa VYM27NR also includes enhanced safety features. It is equipped with multiple safety sensors that provide protection against overheating and electrical surges, ensuring the device operates within safe parameters at all times.

Furthermore, the Desa VYM27NR boasts environmental responsibility with its eco-friendly operating capabilities. It adheres to stringent regulations regarding emissions and energy use, thus aligning with global efforts towards sustainability.

In summary, the Desa VYM27NR showcases a blend of powerful performance, user-friendly features, and safety technologies. Its compact design, efficient energy use, and eco-friendly attributes make it stand out in the market, appealing to a diverse range of users who seek efficiency and reliability in their devices. Whether for personal or professional use, the Desa VYM27NR promises to deliver exceptional performance and value, making it a top choice in its category.