Desa VYM27NR installation manual Installing Logs, Installing Bottom Log #1

Page 13

OWNER’S MANUAL

INSTALLATION

Bottom Log (#1)

Continued

INSTALLING LOGS

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re-

Burner

Port

Grate

Chassis Burner

Figure 16 - Installing Bottom Log (#1)

Top Log (#2)

Peg

Figure 18 - Installing Top Log (#2)

position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place bottom log (#1) on grate to fit as illustrated in Figure 16. Make sure open areas of log set line up with burner ports (see Figure 17). Log will fit securely on chassis. IMPORTANT: Make sure log does not cover any burner ports.

2.Facing front of unit, place top log (#2) onto the pegs in the center of the bot- tom log (see Figure 18).

3.Position log piece (#3) by aligning holes on underside with remaining pegs on bottom log (see Figure 19).

4.Place lava rock around base of heater.

Burner

Log Piece (#3)

Logs

Ports

 

 

Peg

Figure 17 - Installing Log set (Top View)

Figure 19 - Installing Log Piece (#3)

104674

13

Image 13
Contents Remote Control Ready Model OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Patent PendingVanguard Flame MAX Unvented Natural GAS LOG Heater Safety InformationRemote Control Accessories Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsIf Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Mantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Chimney Minimum Permanent Height ft Flue Opening sq. insAttaching Flexible Gas Hose to Heater Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Bottom Log #1 Installing LogsOperating Heater For Your Safety Read Before LightingInstructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerObserved Problem Possible Cause TroubleshootingMaintenance, Observed Problem Possible Cause RemedyGas leak. See Warning statement at top TopSpecifications Wiring Diagram Replacement PartsService Hints Technical ServiceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs VYM27NR Illustrated Parts BreakdownDescription QTY Parts ListAccessories 104674 International Limited Warranty VENT-FREE Natural GAS LOG Heaters

VYM27NR specifications

Desa VYM27NR is a cutting-edge piece of technology designed to meet the demanding needs of modern users while ensuring energy efficiency and superior performance. This innovative device integrates advanced features and smart technologies that make it a popular choice among professionals and consumers alike.

One of the main features of the Desa VYM27NR is its robust performance powered by a high-efficiency motor. This motor is capable of delivering exceptional power output while minimizing energy consumption, which contributes to lower operational costs. The unit operates quietly, making it suitable for use in residential areas without causing disruption.

In addition to its powerful motor, the Desa VYM27NR is equipped with smart sensors that automatically adjust performance based on user requirements. This intelligent adjustment ensures optimal operation, resulting in enhanced user experience. The device also includes an intuitive control panel that allows users to easily monitor and manage settings, further simplifying its use.

Another noteworthy characteristic of the Desa VYM27NR is its compact and lightweight design. This portability allows users to easily move it between different locations or store it without taking up much space. It is constructed from durable materials that ensure longevity and reliability, making it a sound investment for any user.

The technology behind Desa VYM27NR also includes enhanced safety features. It is equipped with multiple safety sensors that provide protection against overheating and electrical surges, ensuring the device operates within safe parameters at all times.

Furthermore, the Desa VYM27NR boasts environmental responsibility with its eco-friendly operating capabilities. It adheres to stringent regulations regarding emissions and energy use, thus aligning with global efforts towards sustainability.

In summary, the Desa VYM27NR showcases a blend of powerful performance, user-friendly features, and safety technologies. Its compact design, efficient energy use, and eco-friendly attributes make it stand out in the market, appealing to a diverse range of users who seek efficiency and reliability in their devices. Whether for personal or professional use, the Desa VYM27NR promises to deliver exceptional performance and value, making it a top choice in its category.