Desa VTD-24N-JHB, VTD-18N-JHB, VTD-30N-JHB Product Identification, Installation, Check GAS Type

Page 5

Product

Identification

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

Log Set

Assembly

Grate

Ceramic

Chassis

Burner

 

Figure 1 - Product Identification (Ramp

Pan Burner)

Installation

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creo- sote will ignite if highly heated. A dirtychimneyfluemaycreateand distribute soot within the house. Inspectchimneyfluefordamage. If damaged, repair flue damper before operating appliance.

NOTICE: Installation, service and repair of this appliance must be performedbyaqualifiedinstaller, service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components listed in these instructions may be used in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Any modifications to or use of unauthorized components or accessory items will void the manufacturer’swarrantyandmay result in a hazardous condition.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, DO NOT install this gas log set.

If the fireplace does not have a gas supply shutoff valve, one must be installed.

WARNING: This appliance is equipped for natural gas. Field conversion is not permitted.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only in a solid-fuel burning fireplace constructed of noncombustible material.

The charts in Figure 2, page 6 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifica- tions shown are applicable before installation is attempted.

The fireplace must include a flue and venting system with the minimum openings shown in Figure 2, page 6.

114370-01Dwww.desatech.com

Image 5
Contents Models VTD-18N-JHB Vtd-24n-jhb Vtd-30n-jhb ApprovedTable of Contents Safety Information Unpacking Local CodesFlue Opening Specifications InstallationProduct Identification Check GAS TypeInstalling Damper Clamp Venting Specifications for InstallationInstallation Items Needed Connecting to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Hearth Kit assembly and installationChecking GAS Connections Repositioning Gas Inlet to Left Side Unit Testing burner for leaksFor Your Safety Read Before Lighting Cleaning MaintenanceOperating Appliance Lighting InstructionsObserved Problem Possible Cause Remedy TroubleshootingStatement at top Gas leak. See WarningTechnical Service Service HintsReplacement Parts AccessoriesModels VTD-18N-JHB, VTD-24N-JHB and VTD-30N-JHB Illustrated Parts BreakdownParts List Limited Warranty Vented GAS Logs Warranty InformationKeep this Warranty

VTD-18N-JHB, VTD-30N-JHB, VTD-24N-JHB specifications

Desa VTD-30N-JHB, VTD-18N-JHB, and VTD-24N-JHB are innovative heating solutions developed for effective space heating in residential and commercial environments. Each model is designed with specific features to cater to a variety of heating needs, ensuring optimal performance and energy efficiency.

The VTD-30N-JHB model stands out for its exceptional heating capacity, making it suitable for larger spaces. With a power output of 30,000 BTU, it is ideal for areas that require substantial warmth during colder months. This model incorporates advanced heating technology, which ensures faster warm-up times and greater airflow distribution. The user-friendly control panel allows for easy temperature adjustments, providing comfort at the touch of a button. Efficiencies in operation contribute to lower energy costs, making it a cost-effective solution for spacious applications.

In contrast, the VTD-18N-JHB offers a balanced performance for medium-sized environments. Its output of 18,000 BTU is sufficient for homes or offices where moderate heating is needed. This unit is equipped with a quiet operation feature, making it perfect for settings where noise reduction is crucial, such as bedrooms or quiet workplaces. Moreover, the VTD-18N-JHB comes with a programmable timer, allowing users to set specific heating schedules according to their daily routines, further enhancing energy savings.

The VTD-24N-JHB serves as a versatile option, bridging the gap between the other two models. With a power output of 24,000 BTU, it is an excellent choice for multi-purpose spaces that require adjustable heating solutions. Its built-in safety measures, such as an automatic shut-off feature and overheat protection, ensure safe operation under various conditions. The model is also designed to function effectively in diverse temperature settings, making it a reliable choice for fluctuating climates.

All three models boast high-quality construction, ensuring durability and longevity. They utilize advanced insulation technologies that minimize heat loss, contributing to their overall efficiency. Additionally, these units are designed with eco-friendly features that comply with modern environmental standards, making them a responsible choice for eco-conscious consumers.

In summary, the Desa VTD series, consisting of the VTD-30N-JHB, VTD-18N-JHB, and VTD-24N-JHB, offers a range of heating solutions tailored to different space requirements. With their combination of innovative technology, user-friendly controls, and eco-friendly design, these heaters provide efficient and effective alternatives for comfortable indoor climates.