Desa VP5B, VP11A installation manual Placing Heater On Mounting Screws

Page 12

INSTALLING TO WALL

Continued

12

Placing Heater On Mounting Screws

1.Locate two keyhole slots on back panel of heater (see Figure 9).

2.Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.

Keyhole Slots

Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater

Removing Front Panel Of Heater

1.Remove two screws near bottom corners of front panel.

2.Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".

3.Pull bottom of front panel forward, then down.

Figure 10 - Removing Front Panel Of Heater

Installing Bottom Mounting Screw

1.Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 11).

2.Mark screw location on wall.

3.Remove heater from wall.

4.If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 5 under Attaching To Wall Anchor Method, page 11.

If installing bottom mounting screw into wall stud, drill hole at marked location using 9/64" drill bit.

5.Replace heater on wall.

6.Insert bottom anchor screw through back panel into bottom anchor or drilled hole (see Figure 11).

7.Tighten screw until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 13-15).

Figure 11 - Installing Bottom Mounting Screw

100844

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DeviceProduct Identification Piezo Ignition SystemFresh AIR for Combustion and Ventilation Producing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation AIR Ventilation Air From OutdoorsInstallation Items Check GAS TypeLocating Heater Installing Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing GAS Supply Piping System Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveFor Your Safety Read Before Lighting Operating HeaterPilot To Select Heating Level Operating Heater Inspecting Burner Pilot Flame PatternShutting Off Heater Shutting Off Burner Only pilot stays litInspecting Burner Cleaning and Maintenance Burner Flame PatternODS/PILOT and Burner Orifice CabinetTrouble Shooting Observed Possible Problem Cause RemedyMaintenance, TROUBLE- ShootingLocate and correct all leaks see Checking Gas Connections, Trouble Shooting Technical Service Ing statement atTop Parts Under Warranty Parts Not Under WarrantyValve GA5010 Parts List Illustrated Parts BreakdownModel VP11A Warranty Information Keep this Warranty

VP5B, VP11A specifications

Desa VP5B and VP11A are innovative and advanced solutions designed to enhance various applications in the energy sector, offering unique features and technologies tailored to meet the modern demands of efficiency and sustainability.

Desa VP5B is a highly efficient power module that stands out for its compact design and integration capabilities. This system is engineered to provide reliable power supply solutions, making it ideal for both residential and commercial applications. One of its most notable features is its modular architecture, which allows for easy scaling as energy needs grow. The system's efficiency is further enhanced by its use of advanced semiconductor technologies, which minimize energy loss during conversion processes. Moreover, the VP5B supports smart grid technologies, enabling seamless interaction with renewable energy sources, which is increasingly crucial in today's energy landscape.

On the other hand, Desa VP11A is designed for robustness and high performance, catering to environments that demand greater power output. This unit boasts a maximum output capacity that makes it suitable for heavy-duty industrial applications. The VP11A employs cutting-edge thermal management systems, ensuring that it operates within optimal temperature ranges, thus prolonging its lifespan and reliability. This model is also equipped with real-time monitoring systems, allowing users to track performance metrics and make informed decisions to optimize energy usage.

Both models prioritize safety, incorporating multiple safety features such as overload protection, over-voltage, and short-circuit protection. They adhere to international safety standards, which is crucial for ensuring the longevity and performance of the systems in varied operational conditions.

From a technological perspective, Desa has invested in advanced communication protocols that allow for integration with IoT devices. This connectivity gives users the ability to remotely monitor and control their power systems, providing greater flexibility and efficiency. The systems can also be configured to operate in coordination with energy management systems, facilitating better load balancing and energy optimization.

In conclusion, Desa VP5B and VP11A represent the forefront of power module technology, combining efficiency, safety, and modern connectivity. Their unique features and robust characteristics position them as essential tools in advancing sustainable energy solutions across a wide range of applications. As we move toward a more energy-conscious future, these systems offer the performance and reliability needed to meet escalating energy demands.