Desa VP5B installation manual Model VP11A

Page 27

PARTS LIST

Model VP11A

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.

KEY

PART

 

 

 

KEY

PART

 

 

NO.

NUMBER

DESCRIPTION

QTY.

NO.

NUMBER

DESCRIPTION

QTY.

1

098304-01

Screw, #10 x 3/8"

2

 

14

100432-01

Control Valve

1

2

099467-01

Front Panel Assembly

1

 

15

099057-01

Pressure Tap Fitting

1

3

099318-03

Grill Guard

1

 

16

098276-01

1/8 Pipe Plug

1

4

098342-01

Grill Guard Clip

2

 

17

099468-05

Cabinet Assembly

1

5

099469-02

Reflector Assembly

1

 

18

099415-02

Gas Regulator

1

6

M15823-37

Screw Hex #8 x 1/4"

10

 

19

098303-02

Screw, #6 x 5/16"

2

7

099059-03

ODS/Pilot Assembly

1

 

20

098508-01

Valve Retainer Nut

1

7-1

098514-01

Thermocouple

1

 

21

099393-01

Control Knob

1

7-2

098594-01

Ignitor Electrode

1

 

22

M11084-26

Screw, #10 x 3/8"

2

8

099884-02

Burner Assembly

1

 

23

099818-01

Internal Tooth Washer

1

9

099056-01

Injector

2

 

24

097159-02

Piezo Ignitor

1

10

099390-02

Tubing - Valve to plaque A

1

 

25

098271-03

Ignitor Cable

1

11

099387-05

Pilot Tubing - Valve to pilot

1

 

 

PARTS AVAILABLE - NOT SHOWN

 

12

099392-01

Tubing - Valve to plaque B

1

 

 

 

 

 

 

 

 

 

 

 

 

 

13

099391-02

Tubing - Regulator to valve

1

 

 

099395-02

Control Position Label

1

 

 

 

 

 

 

 

 

 

ILLUSTRATED

24

17

21

20

PARTS BREAKDOWN

HEATER EXPLODED VIEW

23

Model VP11A

8

4

7

22

25

5

6

3

7-1

7-2

2

1

ODS/PILOT

GRHpv013.U

GRH VP11A

A

25

B

19

6

18

14

15

11

10 16

9 13

9

12

27

100844

Image 27
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationUnconfined Space Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRInstallation Items Check GAS TypeLocating Heater Marking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot To Select Heating Level Shutting Off Burner Only pilot stays lit Operating Heater Inspecting BurnerPilot Flame Pattern Shutting Off HeaterCabinet Inspecting Burner Cleaning and MaintenanceBurner Flame Pattern ODS/PILOT and Burner OrificeObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Maintenance,Locate and correct all leaks see Checking Gas Connections, Trouble Shooting Technical Service Ing statement atTop Parts Under Warranty Parts Not Under WarrantyValve GA5010 Illustrated Parts Breakdown Parts ListModel VP11A Keep this Warranty Warranty Information

VP5B, VP11A specifications

Desa VP5B and VP11A are innovative and advanced solutions designed to enhance various applications in the energy sector, offering unique features and technologies tailored to meet the modern demands of efficiency and sustainability.

Desa VP5B is a highly efficient power module that stands out for its compact design and integration capabilities. This system is engineered to provide reliable power supply solutions, making it ideal for both residential and commercial applications. One of its most notable features is its modular architecture, which allows for easy scaling as energy needs grow. The system's efficiency is further enhanced by its use of advanced semiconductor technologies, which minimize energy loss during conversion processes. Moreover, the VP5B supports smart grid technologies, enabling seamless interaction with renewable energy sources, which is increasingly crucial in today's energy landscape.

On the other hand, Desa VP11A is designed for robustness and high performance, catering to environments that demand greater power output. This unit boasts a maximum output capacity that makes it suitable for heavy-duty industrial applications. The VP11A employs cutting-edge thermal management systems, ensuring that it operates within optimal temperature ranges, thus prolonging its lifespan and reliability. This model is also equipped with real-time monitoring systems, allowing users to track performance metrics and make informed decisions to optimize energy usage.

Both models prioritize safety, incorporating multiple safety features such as overload protection, over-voltage, and short-circuit protection. They adhere to international safety standards, which is crucial for ensuring the longevity and performance of the systems in varied operational conditions.

From a technological perspective, Desa has invested in advanced communication protocols that allow for integration with IoT devices. This connectivity gives users the ability to remotely monitor and control their power systems, providing greater flexibility and efficiency. The systems can also be configured to operate in coordination with energy management systems, facilitating better load balancing and energy optimization.

In conclusion, Desa VP5B and VP11A represent the forefront of power module technology, combining efficiency, safety, and modern connectivity. Their unique features and robust characteristics position them as essential tools in advancing sustainable energy solutions across a wide range of applications. As we move toward a more energy-conscious future, these systems offer the performance and reliability needed to meet escalating energy demands.