Desa VP11A, VP5B installation manual Pilot

Page 17

OPERATING HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 16. If you don’t smell gas, go to the next step.

5. Press in control knob, and turn counterclockwise C-clockwiseto pilot position.

Keep control knob pressed for five seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, refer to Troubleshooting, pages 21 through 24. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match, see Manual Lighting Procedure, page 19.

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 17 - Pilot

7.Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

17

100844

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemProducing Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Ventilation AIRLocating Heater Installation ItemsCheck GAS Type Marking Screw Locations Installing Heater to WallFolding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot To Select Heating Level Pilot Flame Pattern Operating Heater Inspecting BurnerShutting Off Heater Shutting Off Burner Only pilot stays litBurner Flame Pattern Inspecting Burner Cleaning and MaintenanceODS/PILOT and Burner Orifice CabinetObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Maintenance,Locate and correct all leaks see Checking Gas Connections, Top Trouble Shooting Technical ServiceIng statement at Valve GA5010 Parts Under WarrantyParts Not Under Warranty Illustrated Parts Breakdown Parts ListModel VP11A Keep this Warranty Warranty Information

VP5B, VP11A specifications

Desa VP5B and VP11A are innovative and advanced solutions designed to enhance various applications in the energy sector, offering unique features and technologies tailored to meet the modern demands of efficiency and sustainability.

Desa VP5B is a highly efficient power module that stands out for its compact design and integration capabilities. This system is engineered to provide reliable power supply solutions, making it ideal for both residential and commercial applications. One of its most notable features is its modular architecture, which allows for easy scaling as energy needs grow. The system's efficiency is further enhanced by its use of advanced semiconductor technologies, which minimize energy loss during conversion processes. Moreover, the VP5B supports smart grid technologies, enabling seamless interaction with renewable energy sources, which is increasingly crucial in today's energy landscape.

On the other hand, Desa VP11A is designed for robustness and high performance, catering to environments that demand greater power output. This unit boasts a maximum output capacity that makes it suitable for heavy-duty industrial applications. The VP11A employs cutting-edge thermal management systems, ensuring that it operates within optimal temperature ranges, thus prolonging its lifespan and reliability. This model is also equipped with real-time monitoring systems, allowing users to track performance metrics and make informed decisions to optimize energy usage.

Both models prioritize safety, incorporating multiple safety features such as overload protection, over-voltage, and short-circuit protection. They adhere to international safety standards, which is crucial for ensuring the longevity and performance of the systems in varied operational conditions.

From a technological perspective, Desa has invested in advanced communication protocols that allow for integration with IoT devices. This connectivity gives users the ability to remotely monitor and control their power systems, providing greater flexibility and efficiency. The systems can also be configured to operate in coordination with energy management systems, facilitating better load balancing and energy optimization.

In conclusion, Desa VP5B and VP11A represent the forefront of power module technology, combining efficiency, safety, and modern connectivity. Their unique features and robust characteristics position them as essential tools in advancing sustainable energy solutions across a wide range of applications. As we move toward a more energy-conscious future, these systems offer the performance and reliability needed to meet escalating energy demands.