Desa VP10TA VN6D, VP10A VN10TA installation manual OFF Position Shown

Page 13
C-clockwise

OPERATING HEATER (Manual Control Infrared Models)

Manual Lighting Procedure

OPERATING HEATER (Thermostat Control Blue Flame and Infrared Models)

For Your Safety Read Before Lighting

Lighting Instructions

13

OPERATING HEATER

Continued

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 7).

2.Follow steps 1 through 5 under Lighting Instructions, page 12.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 10 seconds after pilot is lit. After 10 seconds, release control knob.

5.Replace front panel.

THERMOSTAT CONTROL BLUE FLAME

AND INFRARED MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

3. Turn control knob clockwise Clockwise to the OFF position (see Figure 22).

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise C-clockwiseto the PILOT position. Press in control knob for five (5) seconds (see Figure 22).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

6.With control knob pressed in, push down and release igni- tor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 16 through 18. Also contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 14.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor Button

 

 

Ignitor Electrode

 

 

Thermocouple

Pilot Burner

Control Knob

 

T

ILOP

LO

 

 

FFO

 

 

 

 

H

 

 

 

 

I

 

 

 

IGNITOR

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

Figure 22 - Control Knob In

Figure 23 - Pilot (Infrared Heater

The OFF Position

Shown)

For more information, visit www.desatech.com

110720-01B

Image 13
Contents What to do if YOU Smell GAS VENT-FREE GAS HeaterSafety Information Table of ContentsUnpacking Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation AIR for CombustionVentilation AIR Ventilation Air From Inside BuildingInstallation Items InstallationCheck GAS Type Locating HeaterInstalling Two Mounting Screws Installing Heater to WallMarking Screw Locations Placing Heater On Mounting ScrewsInstalling Bottom Mounting Screw Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemOperating Heater Pressure Testing Heater Gas ConnectionsLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burner Only pilot stays litBurner Patterns To Select Heating LevelOFF Position Shown Thermostat Control Operation Inspecting BurnerBurner Flame Pattern Blue Flame Models Pilot Flame PatternCleaning Burner Pilot AIR Inlet Hole Cleaning MaintenanceBurner Flame Pattern Infrared Models ODS/PILOT and Burner OrificeObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at VP600BA VP5D VP10A VP10TA VP1000BTA SpecificationsVN600BA VP600BA Pilot Illustrated Parts BreakdownKEY Part Number for VP600BA VN600BA Description QTY Parts ListParts Available not Shown VP10A VN10A KEY Part Number VP10A VN10A Description QTY VP10TA VN10TA KEY Part Number VP10TA VN10TA Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot NJF 8C KEY Part Number VP1000BTA VN1000BTA Description QTYTechnical Service Replacement PartsService Publications Service Hints AccessoryOwners Registration Form Postage Required Baltimore Electric Parts CentralsWarranty Information

VP10TA VN6D, VP10A VN10TA specifications

Desa VP10A, VN10TA, VP10TA, and VN6D are noteworthy models in the realm of cutting-edge technology, designed to cater to modern industrial and consumer needs. Each model boasts unique features and characteristics, making them suitable for various applications.

The Desa VP10A is recognized for its robust performance and high reliability. It typically includes advanced air filtration systems that ensure optimal air quality while maintaining efficient operation. Its energy-efficient design minimizes power consumption without compromising performance, making it an environmentally friendly choice. This model often incorporates user-friendly controls, allowing for effortless adjustments and monitoring of operations.

Moving on to the VN10TA, this unit excels in terms of versatility and adaptability. It is built with a modular design, allowing users to customize the configuration based on specific requirements. This feature enhances its applicability across different sectors, such as manufacturing and logistics. The VN10TA also integrates sophisticated connectivity options, enabling seamless integration with existing systems while providing data analytics capabilities for better operational insights.

The VP10TA model places a strong emphasis on performance efficiency. It includes state-of-the-art technologies such as variable speed drives, which optimize energy use and enhance overall system performance. Moreover, the VP10TA is often equipped with smart sensors that monitor operational parameters in real time, ensuring maximum efficiency and longevity of the unit.

Lastly, the VN6D model stands out with its compact design, perfect for environments with space constraints. Despite its smaller footprint, the VN6D does not compromise on power or efficiency. The unit is designed for quick installation and maintenance, streamlining processes in busy settings. Additionally, it incorporates noise-reduction technologies, making it an excellent choice for applications in noise-sensitive areas.

All models feature high-quality construction materials, ensuring durability and resistance to wear and tear, which is critical in demanding environments. The combination of innovative features and superior technologies in the Desa VP10A, VN10TA, VP10TA, and VN6D makes them valuable assets for any industrial or commercial setup, effectively catering to the intricate demands of today’s economy. Their exceptional performance, adaptability, and efficiency are testaments to Desa's commitment to quality and innovation in technology.