Desa VP10TA VN6D, VP10A VN10TA installation manual KEY Part Number VP10TA VN10TA Description QTY

Page 25

PARTS LIST

VP10TA, VN10TA

25

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual.

KEY

PART NUMBER

 

 

NO.

VP10TA

VN10TA

DESCRIPTION

QTY.

1

098304-01

098304-01

Screw, #10 x 3/8"

2

2

098454-06CD

098454-06CD

Front Panel Assembly

1

3

099318-03

099318-03

Grill Guard

1

4

101108-01

101108-01

Grill Guard Clip

2

5

099275-01

099275-01

Reflector Assembly

1

6

M15823-37

M15823-37

Screw Hex #8 x 1/4"

10

7

099059-03

503329

ODS/Pilot Assembly

1

7-1

098514-01

098514-01

Thermocouple

1

7-2

098594-01

098594-01

Ignitor Electrode

1

8

099884-03

099884-03

Burner Assembly

1

9

099056-25

099056-24

Injector

2

10

104087-01

104087-01

Tubing - Burner

1

11

099387-11

099387-11

Pilot Tubing - Valve to pilot

1

12

M11084-26

M11084-26

Screw, #10 x 3/8"

2

13

104084-01

104084-01

Tubing - Inlet

1

14

098522-16

098522-16

Control Valve

1

15

097159-04

097159-04

Piezo Ignitor

1

16

098271-03

098271-03

Ignitor Cable

1

17

**

**

Cabinet Assembly

1

18

099415-13

099415-12

Gas Regulator

1

19

098303-02

098303-02

Screw, #6 x 5/16"

2

 

 

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

102471-01

102471-01

Control Position Label

1

 

100642-02

100642-02

Assembly, Hardware

1

 

 

 

 

 

** Not a field replaceable part.

For more information, visit www.desatech.com

110720-01B

Image 25
Contents What to do if YOU Smell GAS VENT-FREE GAS HeaterSafety Information Table of ContentsUnpacking Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceVentilation AIR for CombustionVentilation AIR Ventilation Air From Inside BuildingInstallation Items InstallationCheck GAS Type Locating HeaterInstalling Two Mounting Screws Installing Heater to WallMarking Screw Locations Placing Heater On Mounting ScrewsInstalling Bottom Mounting Screw Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemOperating Heater Pressure Testing Heater Gas ConnectionsLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burner Only pilot stays litBurner Patterns To Select Heating LevelOFF Position Shown Thermostat Control Operation Inspecting BurnerBurner Flame Pattern Blue Flame Models Pilot Flame PatternCleaning Burner Pilot AIR Inlet Hole Cleaning MaintenanceBurner Flame Pattern Infrared Models ODS/PILOT and Burner OrificeObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at VP600BA VP5D VP10A VP10TA VP1000BTA SpecificationsVN600BA VP600BA Pilot Illustrated Parts BreakdownKEY Part Number for VP600BA VN600BA Description QTY Parts ListParts Available not Shown VP10A VN10A KEY Part Number VP10A VN10A Description QTY VP10TA VN10TA KEY Part Number VP10TA VN10TA Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot NJF 8C KEY Part Number VP1000BTA VN1000BTA Description QTYTechnical Service Replacement PartsService Publications Service Hints AccessoryOwners Registration Form Postage Required Baltimore Electric Parts CentralsWarranty Information

VP10TA VN6D, VP10A VN10TA specifications

Desa VP10A, VN10TA, VP10TA, and VN6D are noteworthy models in the realm of cutting-edge technology, designed to cater to modern industrial and consumer needs. Each model boasts unique features and characteristics, making them suitable for various applications.

The Desa VP10A is recognized for its robust performance and high reliability. It typically includes advanced air filtration systems that ensure optimal air quality while maintaining efficient operation. Its energy-efficient design minimizes power consumption without compromising performance, making it an environmentally friendly choice. This model often incorporates user-friendly controls, allowing for effortless adjustments and monitoring of operations.

Moving on to the VN10TA, this unit excels in terms of versatility and adaptability. It is built with a modular design, allowing users to customize the configuration based on specific requirements. This feature enhances its applicability across different sectors, such as manufacturing and logistics. The VN10TA also integrates sophisticated connectivity options, enabling seamless integration with existing systems while providing data analytics capabilities for better operational insights.

The VP10TA model places a strong emphasis on performance efficiency. It includes state-of-the-art technologies such as variable speed drives, which optimize energy use and enhance overall system performance. Moreover, the VP10TA is often equipped with smart sensors that monitor operational parameters in real time, ensuring maximum efficiency and longevity of the unit.

Lastly, the VN6D model stands out with its compact design, perfect for environments with space constraints. Despite its smaller footprint, the VN6D does not compromise on power or efficiency. The unit is designed for quick installation and maintenance, streamlining processes in busy settings. Additionally, it incorporates noise-reduction technologies, making it an excellent choice for applications in noise-sensitive areas.

All models feature high-quality construction materials, ensuring durability and resistance to wear and tear, which is critical in demanding environments. The combination of innovative features and superior technologies in the Desa VP10A, VN10TA, VP10TA, and VN6D makes them valuable assets for any industrial or commercial setup, effectively catering to the intricate demands of today’s economy. Their exceptional performance, adaptability, and efficiency are testaments to Desa's commitment to quality and innovation in technology.