Desa VP10TA VN6D, VP10A VN10TA Installing Heater to Wall, Marking Screw Locations

Page 7

INSTALLATION

Continued

THERMOSTAT SENSING BULB (Thermostat Models Only)

The thermostat sensing bulb is located inside the heater. Do not move this bulb during installation or operation of the heater.

INSTALLING HEATER TO WALL

Marking Screw Locations

1.Determine where you will locate heater.

WARNING: Maintain minimum clearances shown in Figure 5. If you can, provide greater clearances from floor and joining wall.

2.Mark two mounting screw locations on wall (see Figure 5).

 

 

8 7/8"

 

 

 

7 3/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

Blue Flame

 

 

 

 

 

 

 

10 7/8" Plaque

 

 

 

 

 

 

 

Minimum To

 

 

 

 

 

 

 

Maintain 6"

 

 

 

 

 

 

WALL

Clearance

Mounting

20 1/4"

 

From Wall

 

 

 

 

 

 

 

 

JOINING

 

 

 

 

Screw

Minimum To

 

 

 

 

Locations

 

 

 

 

 

From Floor

 

 

 

 

 

 

 

 

 

Maintain 3"

 

 

 

 

 

 

 

 

 

Clearance

FLOOR

Figure 5 - Mounting Screw Locations

Installing Two Mounting Screws

Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method

For attaching mounting screw to wall stud

1.Drill hole at marked location using 9/64" drill bit.

2.Insert mounting screw into wall stud.

3.Tighten screw until 1/16" space (thickness of penny) is be- tween screwhead and wall.

Attaching to wall anchor method

Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry).

1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep.

2. Fold wall anchor (see Figure 6).

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

INSTALLATION

7

Thermostat Sensing Bulb (Thermostat Models Only)

Installing Heater To Wall

 

 

 

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 7). IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

5.Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 8).

Thin Walls (1/4" to 1/2" thick)

Figure 6 - Folding Anchor

Figure 7 - Popping Open Anchor

 

Wings For Thin Walls

 

Thin or

 

Thick Wall

 

(thick wall

1/16"

shown)

Space

 

 

Solid

Figure 8 - Tightening Anchors

Wall

 

Placing Heater On Mounting Screws

1.Locate two keyhole slots on back panel of heater (see Figure 9).

2.Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.

Keyhole Slots

Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater

Removing Front Panel Of Heater

1.Remove two screws near bottom corners of front panel.

2.Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".

3.Pull bottom of front panel forward, then down.

Figure 10 - Removing Front Panel Of Heater

For more information, visit www.desatech.com

110720-01B

Image 7
Contents What to do if YOU Smell GAS VENT-FREE GAS HeaterSafety Information Table of ContentsLocal Codes Product FeaturesUnpacking Product IdentificationConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Heater LocationVentilation Air From Inside Building AIR for CombustionVentilation Ventilation AIRLocating Heater InstallationInstallation Items Check GAS TypePlacing Heater On Mounting Screws Installing Heater to WallInstalling Two Mounting Screws Marking Screw LocationsInstalling Bottom Mounting Screw Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemOperating Heater Pressure Testing Heater Gas ConnectionsLighting Instructions Shutting Off Burner Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterBurner Patterns To Select Heating LevelOFF Position Shown Pilot Flame Pattern Inspecting BurnerThermostat Control Operation Burner Flame Pattern Blue Flame ModelsODS/PILOT and Burner Orifice Cleaning MaintenanceCleaning Burner Pilot AIR Inlet Hole Burner Flame Pattern Infrared ModelsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at VP600BA VP5D VP10A VP10TA VP1000BTA SpecificationsVN600BA VP600BA Pilot Illustrated Parts BreakdownKEY Part Number for VP600BA VN600BA Description QTY Parts ListParts Available not Shown VP10A VN10A KEY Part Number VP10A VN10A Description QTY VP10TA VN10TA KEY Part Number VP10TA VN10TA Description QTY VP5D VN6D ODS/PILOT KEY Part Number VP5D VN6D Description QTY VP1000BTA VN1000BTA Pilot NJF 8C KEY Part Number VP1000BTA VN1000BTA Description QTYService Hints Accessory Replacement PartsTechnical Service Service PublicationsOwners Registration Form Postage Required Baltimore Electric Parts CentralsWarranty Information

VP10TA VN6D, VP10A VN10TA specifications

Desa VP10A, VN10TA, VP10TA, and VN6D are noteworthy models in the realm of cutting-edge technology, designed to cater to modern industrial and consumer needs. Each model boasts unique features and characteristics, making them suitable for various applications.

The Desa VP10A is recognized for its robust performance and high reliability. It typically includes advanced air filtration systems that ensure optimal air quality while maintaining efficient operation. Its energy-efficient design minimizes power consumption without compromising performance, making it an environmentally friendly choice. This model often incorporates user-friendly controls, allowing for effortless adjustments and monitoring of operations.

Moving on to the VN10TA, this unit excels in terms of versatility and adaptability. It is built with a modular design, allowing users to customize the configuration based on specific requirements. This feature enhances its applicability across different sectors, such as manufacturing and logistics. The VN10TA also integrates sophisticated connectivity options, enabling seamless integration with existing systems while providing data analytics capabilities for better operational insights.

The VP10TA model places a strong emphasis on performance efficiency. It includes state-of-the-art technologies such as variable speed drives, which optimize energy use and enhance overall system performance. Moreover, the VP10TA is often equipped with smart sensors that monitor operational parameters in real time, ensuring maximum efficiency and longevity of the unit.

Lastly, the VN6D model stands out with its compact design, perfect for environments with space constraints. Despite its smaller footprint, the VN6D does not compromise on power or efficiency. The unit is designed for quick installation and maintenance, streamlining processes in busy settings. Additionally, it incorporates noise-reduction technologies, making it an excellent choice for applications in noise-sensitive areas.

All models feature high-quality construction materials, ensuring durability and resistance to wear and tear, which is critical in demanding environments. The combination of innovative features and superior technologies in the Desa VP10A, VN10TA, VP10TA, and VN6D makes them valuable assets for any industrial or commercial setup, effectively catering to the intricate demands of today’s economy. Their exceptional performance, adaptability, and efficiency are testaments to Desa's commitment to quality and innovation in technology.