Desa B200, REM200, R200 Theory Operation, To Start Heater, To Stop Heater, To Restart Heater

Page 5

OWNER’S MANUAL

THEORY OF

OPERATION

The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.

The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The electronic ignitor sends voltage to the spark plug. The spark plug ignites the fuel and air mixture.

The Flame-out Control System: This system causes the heater to shut down if the flame goes out.

OPERATION

WARNING: Review and un- derstand the warnings in the Safety Information section, page

2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.

TO START HEATER

 

Combustion

Spark

Motor

Air Pump

 

 

Air

 

Chamber

Plug

Burner

Fan

 

Intake

 

 

 

Head

 

 

 

 

 

Filter

 

 

 

 

 

Clean

 

 

 

 

Cool Air

Heated

 

 

 

 

Air Out

 

 

 

 

In

 

 

 

 

 

Air

 

 

 

 

 

Output

 

 

 

 

 

Filter

Fuel

Nozzle

Fuel

 

Air Line

Electronic

Tank

 

Filter

 

To Burner

Ignitor

 

Air For Fuel

 

Air For Combustion

Fuel

 

System

 

And Heating

 

Figure 3 - Cross Section Operational View

1.Follow all ventilation and safety information.

2.Fill fuel tank with kerosene or No. 1 fuel oil.

3.Attach fuel cap.

4.Plug power cord of heater into three- prong, grounded extension cord. Exten- sion cord must be at least six feet long.

Extension Cord Wire Size Requirements

6 to 10 feet long, use 18 AWG rated cord 11 to 100 feet long, use 16AWG rated cord 101 to 200 feet long, use 14AWG rated cord

5.Plug extension cord into standard 120 volt/60 hertz, three-hole, grounded outlet. Heater will start when exten- sion cord is plugged into outlet. If not, push in flame-out control reset button (see Figure 4).

TO STOP HEATER

1.Unplug extension cord from outlet.

TO RESTART HEATER

1.Wait two minutes after stopping heater.

2.Repeat steps under To Start Heater.

Flame-out

Control

Reset

Button

Figure 4 - Flame-out Control Reset Button

102569

5

Image 5
Contents Portable Forced AIR Heater Portable Forced AIR Heater Safety InformationUnpacking Product IdentificationFuels AssemblyVentilation Tools NeededTo Start Heater Theory OperationTo Stop Heater To Restart HeaterStoring TRANSPORTING, or Shipping Preventative MaintenanceSchedule How Often How ToObserved Fault Possible Cause Remedy TroubleshootingPump Pressure Adjustment Service ProceduresUpper Shell Removal FANFuel Valve Fuel FilterNozzle Spark PlugPump Rotor Procedure if Rotor is BindingIllustrated Parts Breakdown Burner Head AssemblyMotor and Pump Assembly KEY Part Number Description QTY Parts ListMaintenance Kits SpecificationsTechnical Service Wheels and Handle Parts ListAccessories Replacement Parts Wiring DiagramWarranty Service Limited WarrantyRepair Service International

REM200, B200, R200 specifications

Desa B200, REM200, and R200 are innovative models from a prominent manufacturer, showcasing advanced technologies and features designed to meet the needs of modern consumers. These models excel in combining performance, efficiency, and user-friendliness.

The Desa B200 is primarily known for its efficiency and high output functionality. Equipped with a robust engine and cutting-edge fuel technology, this model significantly reduces emissions while maintaining high performance levels. The B200 features an intuitive control interface that allows users to easily manage settings, ensuring optimal performance in a wide range of conditions. This product is ideal for residential and light commercial applications, showcasing versatility that caters to diverse user requirements.

On the other hand, the REM200 stands out with its state-of-the-art remote connectivity features. Users can control and monitor the REM200 from their smartphones through a dedicated application, making it convenient for tech-savvy individuals. The integration of IoT (Internet of Things) technology ensures that users receive real-time updates on performance metrics, enhancing operational efficiency. In addition to its connectivity, the REM200 is equipped with safety features that automatically shut down the unit in case of anomalies, protecting users and ensuring longevity of the device.

The R200 model is designed with a focus on portability and user convenience. Weighing less than conventional models in its category, the R200 offers easy mobility without compromising on performance. Its compact design makes it an excellent choice for outdoor enthusiasts, camping trips, or emergency power supply needs. Additionally, the R200 features a durable build that withstands harsh conditions, ensuring reliability in various environments.

All three models integrate advanced energy efficiency technologies to minimize power consumption, making them eco-friendly choices in today's environmentally conscious market. Their design reflects practical ergonomics, allowing for easy operation and maintenance. Combined, the B200, REM200, and R200 create a product line that not only addresses power generation needs but also aligns with sustainable practices.

In conclusion, the Desa B200, REM200, and R200 each offer unique features catered to different user needs. Together, they represent a commitment to innovation in design and technology, setting a benchmark in the power generation industry. Whether users prioritize efficiency, remote connectivity, or portability, these models cover a comprehensive range of applications, making them desirable options in their respective categories.