Remington REM10PT To Turn OFF GAS To Appliance, Thermostat Control Operation, Shutting Off Heater

Page 10

10

OPERATING HEATER

Lighting Instructions

To Turn Off Gas To Appliance

Thermostat Control Operation

Manual Lighting Procedure

OPERATING HEATER

Continued

6.With control knob pressed in, push down and release igni- tor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 13 through 15. Also contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor Button

Control Knob

 

TOILP

LO

 

FFO

 

 

HI

 

IGNITOR

 

 

Figure 16 - Control Knob In The OFF Position

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 17 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on these models differs from stan- dard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO. Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases.

Note: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, instal- lation location, room size, open air temperatures, etc.). Fre- quent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 8, page 5).

2.Follow steps 1 through 5 under Lighting Instructions, page 9.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions.

5.Replace front panel.

For..com

110373-01B

Image 10
Contents REM10PT OWNER’S Operation Installation ManualWhat to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification UnpackingLocal Codes Product FeaturesInstallation PROPANE/LP SupplyInstalling Heater to Wall Thermostat Sensing BulbConnecting to Portable Cylinder GAS Supply Installing Bottom Mounting ScrewConnecting to Permanent GAS Supply Installation ItemsPressure Testing Gas Supply Piping System Permanent GAS SupplyOperating Heater For Your Safety Read Before LightingPressure Testing Heater Gas Connections Checking GAS Connections for Permanent GAS SupplyThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterPilot Flame Pattern Inspecting BurnerStorage Burner Flame PatternODS/PILOT and Burner Cleaning MaintenanceCleaning Burner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Illustrated Parts Breakdown REM10PT PilotParts List REM10PTService Hints SpecificationsTechnical Service Service Publications AccessoriesOwners Registration Form Postage Required 110373-01B Warranty Information