SPECIFICATIONS

TECHNICAL SERVICE

 

SERVICE HINTS

 

SERVICE PUBLICATIONS

 

ACCESSORIES

 

REPLACEMENT PARTS

 

SPECIFICATIONS

 

REM10PT

Btu(Variable)

5,000/10,000

Type Gas

Propane/LP Only

Ignition

Piezo

Internal Regulator Setting

8" W.C.

Inlet Gas Pressure to Heater

 

(inches of water)

14" Max. / 11" Min.

Supply Pressure to Regulator

 

Min (for input adjustment)

10 psi

Max

200 psi

Heater Dimensions

 

(Includes knobs and grill)

21.5" (H) x 13.5" (W) x 7" (D)

Shipping Weight (pounds)

21

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESA International’s technical service web site at www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

ACCESSORIES

Purchase this heater accessory from your local dealer. If they cannot supply this accessory, call DESA International at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

Part Number

Description

LPA3090

Hose/Regulator Assembly

 

U.L. listed.

LPA4020

Fuel Gas Connector

 

Connects regulator to all standard pro-

 

pane tanks. U.L. and A.G.A. listed.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealer from whom you purchased this product. If they cannot supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040 for referral information. When contacting your dealer or DESA International, have ready:

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they cannot supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information. When calling DESA International, have ready:

model number of your heater

the replacement part number

For..com

110373-01B

Image 18
Contents OWNER’S Operation Installation Manual REM10PTWhat to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification UnpackingLocal Codes Product FeaturesInstallation PROPANE/LP SupplyInstalling Heater to Wall Thermostat Sensing BulbConnecting to Portable Cylinder GAS Supply Installing Bottom Mounting ScrewConnecting to Permanent GAS Supply Installation ItemsPressure Testing Gas Supply Piping System Permanent GAS SupplyOperating Heater For Your Safety Read Before LightingPressure Testing Heater Gas Connections Checking GAS Connections for Permanent GAS SupplyThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterPilot Flame Pattern Inspecting BurnerStorage Burner Flame PatternODS/PILOT and Burner Cleaning MaintenanceCleaning Burner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Illustrated Parts Breakdown REM10PT PilotParts List REM10PTService Hints SpecificationsTechnical Service Service Publications AccessoriesOwners Registration Form Postage Required 110373-01B Warranty Information