Remington REM10PT installation manual Maintenance

Page 14

14

TROUBLESHOOTING

TROUBLESHOOTING

Continued

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

Burner does not light after ODS/pilot is lit

1.

Burner orifice is clogged

1.

Clean burner orifice (see Cleaning and

 

 

 

 

 

Maintenance, page 12) or replace burner

 

 

 

 

 

orifice

 

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP gas company

 

 

 

 

 

 

 

Delayed ignition of burner

1.

Manifold pressure is too low

1.

Contact local propane/LP gas company

 

 

2.

Burner orifice is clogged

2.

Clean burner orifice (see Cleaning and

 

 

 

 

 

Maintenance, page 12) or replace burner

 

 

 

 

 

orifice

 

 

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner orifice (see Cleaning and

 

 

 

 

 

Maintenance, page 12) or replace burner

 

 

 

 

 

orifice

 

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP gas company

 

 

3.

Burner damaged

3.

Replace burner

 

 

4.

Gas regulator defective

4.

Replace gas regulator

 

 

 

 

 

 

 

Yellow flame during burner combustion

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

 

Maintenance, page 12)

 

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP gas company

 

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Residues from manufacturing processes

1.

Problem will stop after a few hours of

 

 

 

 

 

operation

 

 

 

 

 

 

 

Heater produces a whistling noise when

1.

Turn control knob to HI position when

1.

Turn control knob to LO position and

 

burner is lit

 

burner is cold

 

let warm up for a minute

 

 

2.

Air in gas line

2.

Operate burner until air is removed

 

 

 

 

 

from line. Have gas checked by local

 

 

 

 

 

propane/LP gas company

 

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

 

ances (see Figure 2, page 4)

 

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 12) or replace burner orifice

For..com

110373-01B

Image 14
Contents What to do if YOU Smell GAS OWNER’S Operation Installation ManualREM10PT Table of Contents Safety InformationProduct Identification UnpackingLocal Codes Product FeaturesInstallation PROPANE/LP SupplyInstalling Heater to Wall Thermostat Sensing BulbConnecting to Portable Cylinder GAS Supply Installing Bottom Mounting ScrewConnecting to Permanent GAS Supply Installation ItemsPressure Testing Gas Supply Piping System Permanent GAS SupplyOperating Heater For Your Safety Read Before LightingPressure Testing Heater Gas Connections Checking GAS Connections for Permanent GAS SupplyThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterPilot Flame Pattern Inspecting BurnerStorage Burner Flame PatternODS/PILOT and Burner Cleaning MaintenanceCleaning Burner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Illustrated Parts Breakdown REM10PT PilotParts List REM10PTService Hints SpecificationsTechnical Service Service Publications AccessoriesOwners Registration Form Postage Required 110373-01B Warranty Information